Installation and Upgrade Guide

NOTE: HP recommends that you do not remove the WBEM Providers for OpenVMS product
even if you do not have a need for it. If you attempt to use the PRODUCT REMOVE command
to remove this product, you might see a message similar to the following. This message is
automatically displayed for any product that is required with OpenVMS; the consequences of
removing WBEM Providers for OpenVMS might not be as severe as implied by the message
unless other software (such as HP SIM) is using the product on your Integrity server.
%PCSI-E-HRDREF, product HP I64VMS WBEMPROVIDERS V1.5 is referenced by HP I64VMS OPENVMS V8.3-1H1
The two products listed above are tightly bound by a software dependency.
If you override the recommendation to terminate the operation, the
referenced product will be removed, but the referencing product will have
an unsatisfied software dependency and may no longer function correctly.
Please review the referencing products documentation on requirements.
Answer YES to the following question to terminate the PRODUCT command.
However, if you are sure you want to remove the referenced product then
answer NO to continue the operation.
Terminating is strongly recommended. Do you want to terminate? [YES]
7.8.7 Configure the Instant Capacity Software (Optional)
Instant Capacity (iCAP) software is supported on cell-based Integrity servers. For support of
this software, as well as Temporary Instant Capacity (TiCAP) , you must configure WBEM
Services for OpenVMS.
If you choose to use Instant Capacity, Temporary Instant Capacity, or Global Instant Capacity,
configure the software by entering the following command:
$ @SYS$MANAGER:ICAP$CONFIG.COM
For more information about configuring and using Instant Capacity, see the HP Instant Capacity
User’s Guide on the following website:
http://docs.hp.com/en/hplex.html#Utility%20Pricing
7.8.8 Configure the Pay per use Software (Optional)
Pay per use (PPU) software is supported on cell-based Integrity servers leased from HP Finance.
For support of this software, you must configure WBEM Services for OpenVMS.
If you choose to use Pay per use, configure the software by entering the following command:
$ @SYS$MANAGER:PPU$CONFIG.COM
For more information about configuring and using Pay per use, see the HP Pay per use User’s
Guide on the following website:
http://docs.hp.com/en/hplex.html#Utility%20Pricing
7.8.9 Configure HP SIM (Optional)
To enable HP SIM support of OpenVMS on your system, follow the directions provided in the
HP WBEM Providers Installation and Adminstrator's Guide, available in the
SYS$COMMON:[WBEMPROVIDERS.DOCUMENTATION] directory on your OpenVMS system
disk. For the latest information, see the documentation provided at the following website:
http://h18002.www1.hp.com/products/servers/management/hpsim/download.html
132 After Installing or Upgrading the OpenVMS Operating System