Instruction Manual

4
Power module configuration
You can determine the number of power modules to be configured for the system
according to the actual power consumption and power supply conditions.
In an environment with two mains power inputs, you can configure N+N
redundant mode.
In an environment with only one mains power input, you can configure N+1 or
N+N redundant mode.
For easy usage and maintenance, be sure to configure a proper circuit breaker for
each power input. The rated current of the circuit breaker must be more than 20 A.
NOTE:
In the term
N+1
and
N+N
, the value of N depends on the number of power module
slots in the device. N+1 or N+N must not be more than the total number of power
module slots.
Installing and removing a power module
Installing a power module
Figure 2 illustrates the flow for installing a power module. Strictly follow the sequence to
avoid possible dangers.