For example, the following would be valid trap decode definitions:
;a3Com_swModuleVerMismatchNotification
[1.3.6.1.4.1.43.47.2.1.0.57]
name= a3Com_swModuleVerMismatchNotification
description= Unit software version {2} mismatch. Expected
version is {1}
explanation= This trap is sent when the software versions on
two units \
in the stack do not match.\
<remedy>Update the agents running on the units in the stack
so they are \
running the same version</remedy>
severity= warning
;a3ComPsePortCurrentStatusTrap - For Switch 4400 PWR
[1.3.6.1.4.1.43.0.142]
name= a3ComPsePortCurrentStatusTrap
description= Port Power over Ethernet current status changed.
explanation= A current port status related to Power over
Ethernet has \
changed to {0,choice,\
1#OK. Neither an under current or over current condition has
\
been detected.|\
2#Over Current. The port current exceeds the maximum
threshold.|\
3#Over Current. The port current exceeds the maximum
threshold.|\
6#Invalid Power over Ethernet Device. An invalid powered
device \
has been detected and will not be delivered power.}
severity= {0,choice, 1#info|2#high|3#high|6#warning}