Chapter 4 Diagnostics
34
Code Description Problem/Solution
0106 Mouse is not
responding.
(The LP 2000r will
complete the boot
process without a
mouse connected.)
The system board has detected the mouse is not responding.
To correct this:
1. If the mouse has just been removed, press [Esc] to
automatically validate the change.
2. Otherwise, verify the mouse connector is firmly connected.
3. If the problem persists, your mouse may need to be replaced.
Contact your service representative.
0108 Mouse and Keyboard
reversed
POST has detected the mouse and keyboard connections are
reversed.
To correct this:
1. Turn the Netserver off.
2. Swap the mouse and keyboard connections.
3. Turn on the Netserver power and reboot the Netserver.
0200 Serial Port Controller
resource conflict
POST has detected an address space or IRQ resource conflict
between one of the integrated serial port controllers and an
accessory board.
To correct this:
1. If an integrated serial port is not needed, run the Setup
Utility and disable the related serial port.
2. If the integrated serial port is needed and its settings cannot
be modified, the accessory board's IRQ and address space
must be reconfigured to use other free resources. Refer to
the accessory board installation manual for information.
0201 Parallel Port
Controller resource
conflict
POST has detected an address space or IRQ resource conflict
between the integrated parallel port controller and an accessory
board.
To correct this:
1. If the integrated parallel port is not needed, run the Setup
Utility and disable the parallel port.
2. If the integrated parallel port is needed and its settings
cannot be modified, the accessory board's IRQ and address
space must be reconfigured to use other free resources.
Refer to the accessory board installation manual for
information.
0300 Flexible disk drive (A)
boot error
POST has detected the flexible disk drive (A) reported an error
during its self-test.
To correct this:
1. Verify a diskette can be properly inserted and removed from
the flexible disk drive.
2. Verify the flexible drive type configured in the Setup Utility
matches the flexible disk drive installed in the HP Netserver.
3. Verify all data cables and power cords are firmly connected.If
the problem persists, your flexible disk drive may need to be
replaced. Contact your service representative.