Chapter 8 Mounting the NetServer in a Rack
51
Type 1--Mounting the Slides
Once you have marked the locations of the slides, attach them. To do so for the
"Type 1" Rack, follow these steps :
◊ First, orient the slides so the slide members extend out the front
of the rack.
◊ Insert screws through the rack column and start them in one bar nut at
the correct location on each column (see Figure 8-5). Prepare to insert
the mounting flange of the slides between the column and the bar nut.
(Refer to Figure 8-6.)
◊ Then line up the front and rear mounting flanges of the slide with the
screws started in the bar nuts. Press the slide firmly against the rack
column. See Figure 8-8.
◊ Tighten all four screws in the mounting flanges of each slide.
Mounting
Flange
Then insert the
mounting flange
in place on
each column and
tighten the screws.
For Type 1 rack, insert
screws through all four rack
columns and start them in bar nuts.
Figure 8-8. Orientation and Fastening of Type 1 Slides