HP MultiSeat Computing Solution
HP Compaq MultiSeat ms6000 Desktop Technical Specifications
DA – XXTBD Worldwide —Version 1 — November 2009
Page 8
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the
extremes of heat and cold, to ensure that unit is operated within the
specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to
permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near
each other that they are subject to each other's re-circulated or preheated
air.
Occasionally clean the air vents on the front, back, and any other vented
side of the computer. Lint, dust and other foreign matter can block the vents
and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust
ventilation must be provided on the enclosure, and the same operating guidelines
listed above will still apply.
Operating: 50° to 95° F (10° to 35° C)
*
Non-operating: -22° to 140° F(-30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude (unpressurized)
Operating: 10,000 ft (3048 m)
Non
-operating: 30,000 ft (9144 m)
* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct
sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and
number of options
installed.
240-watt 89% efficient
*BTX power
supply - Active PFC
Operating Voltage Range
100-240VAC
Rated Voltage Range
115V/230V
Rated Line Frequency
50/60 Hz
Operating Line Frequency Range
47-63 Hz
Rated Input Current
4A
Heat Dissipation (NEED TO UPDATE)
Typical 270 btu/hr
(68 kg-cal/hr)
Maximum 1025 btu/hr
(258 kg-cal/hr)
Power Supply Fan
Variable speed fan
Unit Environment and Operating
Conditions
Temperature Range
Power Supply