QuickSpecs

Unit Environment and
Unit Environment andUnit Environment and
Unit Environment and
Operating Conditions
Operating ConditionsOperating Conditions
Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and
cold, to ensure that unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required
airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are
subject to each other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer.
Lint, dust and other foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be
provided on the enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Temperature RangeTemperature Range
Temperature Range
Operating: 50° to 95°F (10° to 35°C)
*
Non-operating: -22° to 140 F (30° to 60 C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude
Maximum AltitudeMaximum Altitude
Maximum Altitude
(unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Power SupplyPower Supply
Power Supply
240-watt 89% efficient BTX power supply - Active PFC (ms6000/ms6005)
240-watt 90% efficient BTX power supply - Active PFC (ms6200)
Operating Voltage Range
100-240VAC
Rated Voltage Range
115V/230V
Rated Line Frequency
50/60 Hz
Operating Line Frequency
Range
47-63 Hz
Rated Input Current
4A
Heat Dissipation
Typical: 270 btu/hr
(68 kg-cal/hr)
Maximum 1025 btu/hr
(258 kg-cal/hr)
Power Supply Fan
Variable speed fan