Release Notes Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.1.0 (AA-RWF9E-TE, November 2008)
popt post-build-checks procinfo procps psmisc pwdutils rcs readline
readline-devel rpm sed strace sysfsutils sysvinit tar tcpd texinfo timezone
unzip util-linux vim zlib zlib-devel
Prerequisites for SLES 9 SP4
Ensure the fol
lowing RPMs are installed on SLES 9 SP4:
aaa_base acl attr bash bind-utils bison bzip2 coreutils cpio cpp cracklib
cvs cyrus-sasl db devs diffutils e2fsprogs file filesystem fillup findutils
flex gawk gdbm
-devel glibc glibc-devel glibc-locale gpm grep groff gzip
info insserv kbd less libacl libattr libgcc libselinux libstdc++ libxcrypt
m4 make man mktemp module-init-tools ncurses ncurses-devel net-tools netcfg
openldap2-c
lient openssl pam pam-modules patch permissions popt procinfo
procps psmisc pwdutils rcs readline sed strace syslogd sysvinit tar tcpd
texinfo timezone unzip util-linux vim zlib zlib-devel autoconf automake
binutils dev
ice-mapper gcc gdbm gettext libtool perl readline-devel rpm
termcap udev
Installing HPDM Multipath Enablement kit 4.1.0
To install HPDM Multipath 4 .1.0, complete the following steps:
1. Download the HPDM Multipath Enablement Kit for H P StorageWorks Disk Arrays v4.1.0
available at h
ttp://www.hp.com/go/devicemapper.
2. Log in as root to the host system.
3. Copy the installation tar package to a temporary directory (for instance,
/tmp/HPDMmultipath).
4. Unbundle the package by executing the following commands:
#cd /tmp/HPDMmultipath
#tar -xvzf HPDMmultipath-4.1.0.tar.gz
#cd HPDMmultipath-4.1.0
5. Verify that the directory contains README.txt, COPYING, INSTALL, bin, conf, SRPMS,
and docs directories.
6. To install HPDM Multipath v4.1.0, execute the following command:
#./INSTALL
Configuri
ng Device Mapper Multipath to enable HP arrays
This sec
tion describes the following:
• Recommended device parameter values
• Setting up HPDM Multipath
• Setting
up Device Mapper Multipath daemon
Recommended device parameter values
To enable the HP a rrays, edit /etc/multipath.conf fi le by adding the following under devices
section:
6
Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays