Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.2.1 release notes (AA-RWF9H-TE, March 2009)

For MSA2012fc/MSA2212fc/MSA2012i
device
{
vendor "HP"
product "MSA2[02]12fc|MSA2012i"
path_grouping_policy multibus
getuid_callout "/lib/udev/scsi_id -g -u /dev/%n"
path_selector "round-robin 0"
rr_weight uniform
path_checker tur
hardware_handler "0"
failback immediate
no_path_retry 18
rr_min_io 100
}
For MSA2312fc/MSA2324fc
device
{
vendor "HP"
product "MSA2312fc|MSA2324fc"
getuid_callout "/lib/udev/scsi_id -g -u /dev/%n"
hardware_handler "0"
path_selector "round-robin 0"
prio alua
path_grouping_policy group_by_prio
failback immediate
rr_weight uniform
no_path_retry 18
rr_min_io 100
path_checker tur
}