User guide

HP P2000 G3 FC/iSCSI MSA System User Guide 39
To connect the P2000 G3 FC/iSCSI MSA System to a server or HBA switch — using the controller’s iSCSI
host ports — select the appropriate qualified 1Gb option (see Quickspecs).
Single controller configuration
One server/one HBA/single path
Dual controller configurations
One server/one HBA/dual path
4Gbps
70m with 62.5μm fiber type X
150 m w i t h 50 μm fiber type X
380m with 50μm fiber type X
2Gbps
150 m w i t h 62. 5 μm fiber type X
300m with 50μm fiber type X
500m with 50μm fiber type X
Table 5 Maximum cable lengths for 850nm Fibre Channel SFP transceivers
SFP data Representative FC cable types
Cable performance code
Data rate
MMF FC cable length designators
OM1 OM2 OM3
6Gb/s
6Gb/s
Server
Server
6Gb/s
6Gb/s
6Gb/s
6Gb/s
Server
Server