NDIERR 191 MESSAGE: Error in Network Directory intrinsic; check for error
status. (NDIERR 191)
CAUSE: This is an internal error.
ACTION: Refer to the accompanying NMCONF error message. If the
associated error is number 58, then the configuration file to merge from
does not have any directory data in it. The file must first be read by the
network transport by bringing up the transport in order to extract the
directory data.
NDIERR 192 MESSAGE: Requires Network Administrator capability. (NDIERR 192)
CAUSE: User does not have Network Administrator capabilities.
ACTION: Change user capabilities.
NDIERR 200 MESSAGE: File recovery: cannot open message catalog.
(NDIERR 200)
CAUSE: The message catalog NMMGRCAT.PUB.SYS could not be opened.
Possible CAUSEs include: improper product installation, insufficient
user access rights to the catalog file, or an incorrect version of the
software installed.
ACTION: Reinstall the product, increase the user’s access rights, or
restore NMMGRCAT.PUB.SYS from a backup tape.
NDIERR 201 MESSAGE: File recovery: FOPEN of temporary command file failed.
(NDIERR 201)
CAUSE: MPE could not open a scratch file to write file recovery
commands into. This could be CAUSEd by one or more of the following
reasons:
• Duplicate file name. BeCAUSE the file name generated is random,
this CAUSE is very unlikely.
• User does not have Save Files capability.
• Other file system error.
ACTION: 1. Consult the associated file system error for problem
resolution.
ACTION: 2. Attempt manual recovery of the directory file using
KSAMUTIL.PUB.SYS.
NDIERR 202 MESSAGE: File recovery: GEMMESSAGE failed. (NDIERR 202)
CAUSE: Could not read a message from the catalog NMMGRCAT.PUB.SYS.
A possible CAUSE is that an incorrect version of the software is
installed.
ACTION: Reinstall the product, restore NMMGRCAT.PUB.SYS, or attempt
manual recovery of the directory file using KSAMUTIL.PUB.SYS.