Using the Node Management Services (NMS) Utilities (MPE/iX 7.0, 7.5)

278 AppendixA
NMS Error Messages
NMMGRVER Messages, Errors and Warnings
NMMGRVERERR
20
MESSAGE: Unable to purge LINKCONF subtree (NMMGRVERERR 20)
CAUSE: Internal error. File has been converted. However, in the attempt
to purge the subtree LINKCONF, the NM intrinsic failed.
ACTION: The configuration file may be corrupted. Restore a backup
copy of the configuration file if possible and run NMMGRVER again. If
the error still occurs, see “Submitting a CR” at the beginning of this
appendix.
NMMGRVERERR
21
MESSAGE: Error accessing NMMGRCAT.PUB.SYS set=! msg=!.
(NMMGRVERERR 21)
CAUSE: Returned by NMCPRINTERRMSG. Usually followed by one or
more of messages 22 through 25 below, which further clarifies the error.
ACTION: Look for one or more of NMMGRVERERR 22 through 25
following this message, and take the remedial action suggested below.
Look up the text and comments for the original message specified in the
message, and take the suggested actions.
NMMGRVERERR
22
MESSAGE: FOPEN FSERR ! on NMMGRCAT.PUB.SYS.
(NMMGRVERERR 22)
CAUSE: Returned by NMCPRINTERRMSG and usually followed by the
text of the FSError message.
ACTION: If the error number is 1 or 2, NMMGRVERERR 24 will also be
displayed. See the NMMGRVERERR 24 causes and actions for further
information. Returned by NMCPRINTERRMSG.
NMMGRVERERR
23
MESSAGE: Encountered GENMESSAGE error !. (NMMGRVERERR 23)
CAUSE: Possible bad software installation (NMMGRCAT.PUB.SYS).
ACTION: If the error number is not 1 or 2, look up the error number in
the MPE Intrinsics Manual under GENMESSAGE. The problem may
be due to a corrupt NMMGRCAT.PUB.SYS. Restore NMMGRCAT.PUB.SYS
and run NMMGRVER again. Otherwise, correct the problem causing
the GENMESSAGE error and run NMMGRVER again.
NMMGRVERERR
24
MESSAGE: GENMESSAGE encountered FSERR !.
(NMMGRVERERR 24)
CAUSE: Returned by NMCPRINTERRMSG. This message follows
NMMGRVERERR 23 message, and is usually followed with the text of
the file system error message as well.
ACTION: Correct the file system error and run NMMGRVER again.
NMMGRVERERR
25
MESSAGE: FCLOSE FSERR ! on NMMGRCAT.PUB.SYS.
(NMMGRVERERR 25)
CAUSE: Returned by NMCPRINTERRMSG after printing a message
from NMMGRCAT.PUB.SYS. The FCLOSE of NMMGRCAT.PUB.SYS failed.
ACTION: Correct the file system error and run NMMGRVER again.