Using the Node Management Services (NMS) Utilities (MPE/iX 7.0, 7.5)

242 AppendixA
NMS Error Messages
NMGR Error and Warning Messages
NMGRERR 205 MESSAGE: Aux file does not contain specified path. (NMGRERR 205)
CAUSE: This is a guided configuration error caused when NMMGRCAT
specifies a path in the auxiliary file that does not exist.
ACTION: Copy NMAUX1.PUB.SYS from backup tape, and run
NMAINT.PUB.SYS to make sure that the version of NMAUX1 is the same
as the version of NMMGR.
NMGRERR 206 MESSAGE: Path to subtree in user file does not exist.
(NMGRERR 206)
CAUSE: This problem could be caused by a corrupt file or by an old
configuration file that needs to be updated.
ACTION: Run NMMGRVER.PUB.SYS. If needed, restore a known good
configuration file from a backup tape, or create a new configuration file
with NMMGR.
NMGRERR 207 MESSAGE: Internal error; Guided token overflow. (NMGRERR 207)
CAUSE: This is an internal guided configuration error.
ACTION: Restore NMMGRCAT.PUB.SYS from a backup tape. If this fails
see “Submitting a CR” at the beginning of this appendix.
NMGRERR 208 MESSAGE: Unexpected Guided Config error. (NMGRERR 208)
CAUSE: An unexpected or internal guided configuration error occurred.
ACTION: Type the ERROR command after this message is displayed for
clarification of the error(s). A PC value is specified at the end of this
error message. If unable to include the value problem, submit a CR
(Change Request). See “Submitting a CR” at the beginning of this
appendix. Be sure to include the value of the PC with the CR.
NMGRERR 209 MESSAGE: Cannot Stop Guided Configuration. (NMGRERR 209)
CAUSE: The STOP command is allowed only on screens which contain a
“path.” This is most likely to occur when the user types the command
STOP on the errors screen during guided configuration.
ACTION: Move to a screen which contains a “path” at the top of the
menu and retype the stop command.
NMGRERR 211 MESSAGE: Cannot perform NEXT function. (NMGRERR 211)
CAUSE: This error occurs when the user attempts to use the NEXT
command when no selection screen has been encountered.
ACTION: There is no need to use this function at this time.
NMGRERR 214 MESSAGE: Function is not allowed during Guided configuration.
(NMGRERR 214)
CAUSE: The user has pressed a function key that is not allowed during
guided configuration. If the user is on a data screen, it is possible to
advance by pressing the Update function key.