Using the Node Management Services (NMS) Utilities (MPE/iX 7.0, 7.5)
Appendix A 223
NMS Error Messages
NMGR Error and Warning Messages
NMGRWARN 17 MESSAGE: No errors have yet occurred. (NMGRWARN 17)
CAUSE: The user has gone to the ERRORS screen to check the last
error, but no errors have occurred.
ACTION: None.
NMGRERR 19 MESSAGE: MPE command error. (NMGRERR 19)
CAUSE: The user executed an MPE command (by entering the command
preceded by a colon and pressing ENTER), and the command
terminated in an error state.
ACTION: Use the Error Information screen and check the Command
Interpreter error for further information.
NMGRERR 20 MESSAGE: Item does not exist: use the ADD key to create a new item.
(NMGRERR 20)
CAUSE: The user tried to DELETE, RENAME, or UPDATE an item in a
select screen, but the item does not exist in the configuration file.
ACTION: Use the ADD key if you intend to add the new item; otherwise
check the spelling of the item name.
NMGRERR 21 MESSAGE: Item already exists. (NMGRERR 21)
CAUSE: The user tried to ADD an item in a select screen, but the item
already exists.
ACTION: Check the spelling of the item name.
NMGRERR 22 MESSAGE: Cannot open NM configuration file. (NMGRERR 22)
CAUSE: A file system error occurred.
ACTION: Go to the Errors screen and check for a file system error
(FSERR). Correct the error and try again.
CAUSE: The NMFILE.PUB.SYS process of the Node Management
Services is not running.
ACTION: Go to the Errors screen and check for FSERR 97. If this error
occurred, the problem may be due to a version mismatch in the NMS
subsystem. See “Invalid Software Installation” at the beginning of this
appendix.
NMGRERR 23 MESSAGE: Cannot reopen NM configuration file. (NMGRERR 23)
CAUSE: NMMGR was unable to reopen the configuration file after
closing it for compression.
ACTION: Check the NMCONF or File System error (if one is reported)
for further information. This error is fatal and cannot be recovered
except by running NMMGR again. See message NMGRERR 22.