TurboIMAGE/XL Database Management System Reference Manual (30391-90012)
Table Of Contents
- 1 Introduction
- 2 Database Structure and Protection
- 3 Defining a Database
- 4 Using the Database
- 5 TurboIMAGE/XL Library Procedures
- Using TurboIMAGE/XL Intrinsics
- DBBEGIN
- DBCLOSE
- DBCONTROL
- DBDELETE
- DBEND
- DBERROR
- DBEXPLAIN
- DBFIND
- DBGET
- DBINFO
- INTRINSIC NUMBER 402
- Syntax
- Parameters
- Discussion
- Mode 101: Item Number
- Mode 102: Item Name
- Mode 103: Items in Database
- Mode 104: Items in Data Set
- Mode 113: BTREEMODE1 and Wildcard Character
- Mode 201: Set Number
- Mode 202: Set Name
- Mode 203: Sets in Database
- Mode 204: Sets with Item
- Mode 205: Set Capacity
- Mode 206: Number of Data Set Chunks
- Mode 207: Size of Data Set Chunks
- Mode 208: Primary and Actual Capacity
- Mode 209: B-Tree Attachment
- Mode 301: Paths
- Mode 302: Key or Search Item
- Mode 401: Logging
- Mode 402: ILR
- Mode 403: Dynamic Roll-Back
- Mode 404: Logging Subsystem Information
- Mode 406: Database Information
- Mode 501: Subsystem Access
- Mode 502: Critical Item Update
- Modes 8nn: Third-Party Indexing
- Mode 901: Language
- DBLOCK
- DBMEMO
- DBOPEN
- DBPUT
- DBUNLOCK
- DBUPDATE
- DBXBEGIN
- DBXEND
- DBXUNDO
- 6 Host Language Access
- Model Program
- ORDERS Database Model Program
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- C
- COBOL II
- Defining Data Types, Variables, and Intrinsics
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- FORTRAN 77
- Pascal
- RPG
- 7 Logging and Recovery
- Database Utilities Used in Logging and Recovery
- Recovery Options
- Logical Transactions
- Dynamic Roll-Back Recovery
- Intrinsic Level Recovery
- Logging Preparation
- Step 1--Checking MPE/iX Logging Configuration
- Step 2--Acquiring Logging Capability
- Step 3--Logging to Tape or Disk
- Step 4--Building a Log File for Logging to Disk
- Step 5--Creating the Log Identifier
- Step 6--Setting the Log Identifier
- Step 7--Setting Flags for the Database Backup Copy
- Step 8--Making a Database Backup Copy
- TurboSTORE/iX 7x24 True-Online Backup
- Logging Status
- Logging Maintenance
- Roll-Forward Recovery
- Roll-Back Recovery
- DBRECOV Commands Used with Roll-Forward and Roll-Back Recovery
- Recovery Tables
- Post-Recovery Options
- The Mirror Database
- 8 Using the Database Utilities
- Restructuring the Database with TurboIMAGE/XL Utilities
- Summary of Utility Routines
- Utility Program Operation
- DBLOAD
- DBRECOV
- >CONTROL
- >EXIT
- >FILE
- >RECOVER
- >ROLLBACK
- >RUN
- DBRESTOR
- DBSTORE
- DBUNLOAD
- DBUTIL
- >>ACTIVATE
- >>ADDINDEX
- >>CREATE
- >>DEACTIVATE
- >>DETACH
- >>DISABLE
- >>DROPINDEX
- >>ENABLE
- >>ERASE
- >>EXIT
- >>HELP
- >>MOVE
- >>PURGE
- >>REBUILDINDEX
- >>REDO
- >>RELEASE
- >>SECURE
- >>SET
- >>SHOW
- Syntax
- Parameters
- Example (Show Users)
- Example Discussion
- Example (Show All)
- Example Discussion
- Example (Show Capacity)
- Format of Show Device List
- Example (Show Device)
- Format of Show Indices
- Example (Show Indices)
- Format of Show Locks List
- Example 1 (Show Locks)
- Example 1 Discussion
- Example 2 (Show Locks)
- Example 2 Discussion
- >>VERIFY
- 9 Using a Remote Database
- 10 Internal Structures and Techniques
- 11 B-Tree Indices
- A Error Messages
- B Results of Multiple Access
- C Database Design Considerations
- D Multiple Calls to DBLOCK
- E TurboIMAGE/XL Log Record Formats
- F MPE/iX Log Record Formats
- G Recovery and Logging Quick Reference
- H TurboIMAGE/XL versus TurboIMAGE/V

Appendix A 613
Error Messages
Utility Error Messages
MESSAGE INCOMPLETE DBNAME2
MEANING The file name or group name is followed by a period and the rest of the
record is empty. Or the next character is a semicolon (;).
ACTION Use EDITOR to change the FILE command.
MESSAGE INCOMPLETE LOCAL PART
MEANING The period following the local user name was missing, or the account name
was missing, or a comma followed the account name and the group name
was missing.
ACTION Use EDITOR to change the HELLO command in the RDBA access file.
MESSAGE INCOMPLETE REMOTE PART
MEANING The period following the
rusername
was missing, or the
raccountname
was missing, or the
raccountname
was followed by a comma and the
rgroupname
was missing.
ACTION Use EDITOR to change the HELLO command in the RDBA access file.
MESSAGE INSUFFICIENT DISC SPACE
MEANING The amount of disk space required for the database is not available on the
system.
ACTION Consult with the database administrator about disk space requirements.
MESSAGE INSUFFICIENT VIRTUAL MEMORY
MEANING Not enough virtual memory is available to open and access the database.
ACTION Try running the utility later when the system is not as busy.
MESSAGE INTERNAL ERROR--DATABASE CONTAINS INVALID LOGGING
IDENTIFIER
MEANING The logging ID configured in the database through DBUTIL is not
configured through the MPE GETLOG command.
ACTION Contact your database administrator.
MESSAGE INVALID ACCESS CLASS NUMBER
MEANING The access class should be a number between 1 and 63.
ACTION Reenter with a valid access class number.