TurboIMAGE/XL Database Management System Reference Manual (30391-90012)
Table Of Contents
- 1 Introduction
- 2 Database Structure and Protection
- 3 Defining a Database
- 4 Using the Database
- 5 TurboIMAGE/XL Library Procedures
- Using TurboIMAGE/XL Intrinsics
- DBBEGIN
- DBCLOSE
- DBCONTROL
- DBDELETE
- DBEND
- DBERROR
- DBEXPLAIN
- DBFIND
- DBGET
- DBINFO
- INTRINSIC NUMBER 402
- Syntax
- Parameters
- Discussion
- Mode 101: Item Number
- Mode 102: Item Name
- Mode 103: Items in Database
- Mode 104: Items in Data Set
- Mode 113: BTREEMODE1 and Wildcard Character
- Mode 201: Set Number
- Mode 202: Set Name
- Mode 203: Sets in Database
- Mode 204: Sets with Item
- Mode 205: Set Capacity
- Mode 206: Number of Data Set Chunks
- Mode 207: Size of Data Set Chunks
- Mode 208: Primary and Actual Capacity
- Mode 209: B-Tree Attachment
- Mode 301: Paths
- Mode 302: Key or Search Item
- Mode 401: Logging
- Mode 402: ILR
- Mode 403: Dynamic Roll-Back
- Mode 404: Logging Subsystem Information
- Mode 406: Database Information
- Mode 501: Subsystem Access
- Mode 502: Critical Item Update
- Modes 8nn: Third-Party Indexing
- Mode 901: Language
- DBLOCK
- DBMEMO
- DBOPEN
- DBPUT
- DBUNLOCK
- DBUPDATE
- DBXBEGIN
- DBXEND
- DBXUNDO
- 6 Host Language Access
- Model Program
- ORDERS Database Model Program
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- C
- COBOL II
- Defining Data Types, Variables, and Intrinsics
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- FORTRAN 77
- Pascal
- RPG
- 7 Logging and Recovery
- Database Utilities Used in Logging and Recovery
- Recovery Options
- Logical Transactions
- Dynamic Roll-Back Recovery
- Intrinsic Level Recovery
- Logging Preparation
- Step 1--Checking MPE/iX Logging Configuration
- Step 2--Acquiring Logging Capability
- Step 3--Logging to Tape or Disk
- Step 4--Building a Log File for Logging to Disk
- Step 5--Creating the Log Identifier
- Step 6--Setting the Log Identifier
- Step 7--Setting Flags for the Database Backup Copy
- Step 8--Making a Database Backup Copy
- TurboSTORE/iX 7x24 True-Online Backup
- Logging Status
- Logging Maintenance
- Roll-Forward Recovery
- Roll-Back Recovery
- DBRECOV Commands Used with Roll-Forward and Roll-Back Recovery
- Recovery Tables
- Post-Recovery Options
- The Mirror Database
- 8 Using the Database Utilities
- Restructuring the Database with TurboIMAGE/XL Utilities
- Summary of Utility Routines
- Utility Program Operation
- DBLOAD
- DBRECOV
- >CONTROL
- >EXIT
- >FILE
- >RECOVER
- >ROLLBACK
- >RUN
- DBRESTOR
- DBSTORE
- DBUNLOAD
- DBUTIL
- >>ACTIVATE
- >>ADDINDEX
- >>CREATE
- >>DEACTIVATE
- >>DETACH
- >>DISABLE
- >>DROPINDEX
- >>ENABLE
- >>ERASE
- >>EXIT
- >>HELP
- >>MOVE
- >>PURGE
- >>REBUILDINDEX
- >>REDO
- >>RELEASE
- >>SECURE
- >>SET
- >>SHOW
- Syntax
- Parameters
- Example (Show Users)
- Example Discussion
- Example (Show All)
- Example Discussion
- Example (Show Capacity)
- Format of Show Device List
- Example (Show Device)
- Format of Show Indices
- Example (Show Indices)
- Format of Show Locks List
- Example 1 (Show Locks)
- Example 1 Discussion
- Example 2 (Show Locks)
- Example 2 Discussion
- >>VERIFY
- 9 Using a Remote Database
- 10 Internal Structures and Techniques
- 11 B-Tree Indices
- A Error Messages
- B Results of Multiple Access
- C Database Design Considerations
- D Multiple Calls to DBLOCK
- E TurboIMAGE/XL Log Record Formats
- F MPE/iX Log Record Formats
- G Recovery and Logging Quick Reference
- H TurboIMAGE/XL versus TurboIMAGE/V

Appendix A 533
Error Messages
Schema Processor Error Messages
MESSAGE ILLEGAL USER CLASS NUMBER
MEANING User class number defined in schema password part is not an integer
between 1 and 63.
ACTION Examine the schema text file to find the error. Edit the text file, and run
the Schema Processor again.
MESSAGE INCREMENT NUMBER TOO LARGE
MEANING The increment number of entries, or the entries calculated from the
percent, exceeded maximum capacity minus initial capacity.
ACTION Change the increment amount to a smaller number.
MESSAGE INCREMENT PARAMETER IGNORED (INITCAP = MAXCAP)
MEANING The increment parameter is not used, since initial capacity is equal to
maximum capacity and expansion is not on.
ACTION Warning only; delete the increment parameter.
MESSAGE INCREMENT PARAMETER NOT ALLOWED
MEANING The increment capacity parameter can only be defined if the initial
capacity parameter is also defined.
ACTION Either specify a number for initial capacity along with the increment, or do
not specify the increment parameter. Defining initial capacity and
increment option means allowing dynamic expansion for the data set.
MESSAGE INITIAL CAPACITY = MAXIMUM CAPACITY, NO EXPANSION
MEANING The initial capacity is equal to the maximum capacity, no dynamic
expansion for the data set.
ACTION Warning only.
MESSAGE INITIAL CAPACITY EXCEEDS MAXIMUM CAPACITY
MEANING The initial capacity defined is greater than maximum capacity.
ACTION Either change the maximum capacity or the initial capacity. Initial
capacity must be less than or equal to the maximum capacity.
MESSAGE ITEM LENGTH NOT INTEGRAL WORDS
MEANING Item length is not in an even number of bytes.
ACTION Examine the schema text file to find the error. Edit the text file, and run