TurboIMAGE/XL Database Management System Reference Manual (30391-90012)
Table Of Contents
- 1 Introduction
- 2 Database Structure and Protection
- 3 Defining a Database
- 4 Using the Database
- 5 TurboIMAGE/XL Library Procedures
- Using TurboIMAGE/XL Intrinsics
- DBBEGIN
- DBCLOSE
- DBCONTROL
- DBDELETE
- DBEND
- DBERROR
- DBEXPLAIN
- DBFIND
- DBGET
- DBINFO
- INTRINSIC NUMBER 402
- Syntax
- Parameters
- Discussion
- Mode 101: Item Number
- Mode 102: Item Name
- Mode 103: Items in Database
- Mode 104: Items in Data Set
- Mode 113: BTREEMODE1 and Wildcard Character
- Mode 201: Set Number
- Mode 202: Set Name
- Mode 203: Sets in Database
- Mode 204: Sets with Item
- Mode 205: Set Capacity
- Mode 206: Number of Data Set Chunks
- Mode 207: Size of Data Set Chunks
- Mode 208: Primary and Actual Capacity
- Mode 209: B-Tree Attachment
- Mode 301: Paths
- Mode 302: Key or Search Item
- Mode 401: Logging
- Mode 402: ILR
- Mode 403: Dynamic Roll-Back
- Mode 404: Logging Subsystem Information
- Mode 406: Database Information
- Mode 501: Subsystem Access
- Mode 502: Critical Item Update
- Modes 8nn: Third-Party Indexing
- Mode 901: Language
- DBLOCK
- DBMEMO
- DBOPEN
- DBPUT
- DBUNLOCK
- DBUPDATE
- DBXBEGIN
- DBXEND
- DBXUNDO
- 6 Host Language Access
- Model Program
- ORDERS Database Model Program
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- C
- COBOL II
- Defining Data Types, Variables, and Intrinsics
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- FORTRAN 77
- Pascal
- RPG
- 7 Logging and Recovery
- Database Utilities Used in Logging and Recovery
- Recovery Options
- Logical Transactions
- Dynamic Roll-Back Recovery
- Intrinsic Level Recovery
- Logging Preparation
- Step 1--Checking MPE/iX Logging Configuration
- Step 2--Acquiring Logging Capability
- Step 3--Logging to Tape or Disk
- Step 4--Building a Log File for Logging to Disk
- Step 5--Creating the Log Identifier
- Step 6--Setting the Log Identifier
- Step 7--Setting Flags for the Database Backup Copy
- Step 8--Making a Database Backup Copy
- TurboSTORE/iX 7x24 True-Online Backup
- Logging Status
- Logging Maintenance
- Roll-Forward Recovery
- Roll-Back Recovery
- DBRECOV Commands Used with Roll-Forward and Roll-Back Recovery
- Recovery Tables
- Post-Recovery Options
- The Mirror Database
- 8 Using the Database Utilities
- Restructuring the Database with TurboIMAGE/XL Utilities
- Summary of Utility Routines
- Utility Program Operation
- DBLOAD
- DBRECOV
- >CONTROL
- >EXIT
- >FILE
- >RECOVER
- >ROLLBACK
- >RUN
- DBRESTOR
- DBSTORE
- DBUNLOAD
- DBUTIL
- >>ACTIVATE
- >>ADDINDEX
- >>CREATE
- >>DEACTIVATE
- >>DETACH
- >>DISABLE
- >>DROPINDEX
- >>ENABLE
- >>ERASE
- >>EXIT
- >>HELP
- >>MOVE
- >>PURGE
- >>REBUILDINDEX
- >>REDO
- >>RELEASE
- >>SECURE
- >>SET
- >>SHOW
- Syntax
- Parameters
- Example (Show Users)
- Example Discussion
- Example (Show All)
- Example Discussion
- Example (Show Capacity)
- Format of Show Device List
- Example (Show Device)
- Format of Show Indices
- Example (Show Indices)
- Format of Show Locks List
- Example 1 (Show Locks)
- Example 1 Discussion
- Example 2 (Show Locks)
- Example 2 Discussion
- >>VERIFY
- 9 Using a Remote Database
- 10 Internal Structures and Techniques
- 11 B-Tree Indices
- A Error Messages
- B Results of Multiple Access
- C Database Design Considerations
- D Multiple Calls to DBLOCK
- E TurboIMAGE/XL Log Record Formats
- F MPE/iX Log Record Formats
- G Recovery and Logging Quick Reference
- H TurboIMAGE/XL versus TurboIMAGE/V

Appendix A 529
Error Messages
Schema Processor Error Messages
MESSAGE BAD PATH SPECIFICATION DELIMITER
MEANING Name of master data set following search item name in detail data set
definition is not followed by a right parenthesis ")" or by a sort item name
in parentheses.
ACTION Examine the schema text file to find the error. Edit the text file, and run
the Schema Processor again.
MESSAGE BAD READ CLASS OR TERMINATOR
MEANING Read user class number defined for either a data set or data item is not an
integer from 0 to 63, or it is not terminated by a comma (,) or slash (/).
ACTION Examine the schema text file to find the error. Edit the text file, and run
the Schema Processor again.
MESSAGE BAD SET NAME OR TERMINATOR
MEANING The data set name does not conform to naming rules. (Names must start
with a letter and can have up to 16 alphanumeric characters including + −
∗ / ? ∋ # % & @.) Or the data set name is not terminated by the correct
character for the context in which it appears.
ACTION Examine the schema text file to find the error. Edit the text file, and run
the Schema Processor again.
MESSAGE BAD SUBITEM COUNT OR TERMINATOR
MEANING Subitem count for a data item defined in schema item part is not an
integer from 1 to 255.
ACTION Examine the schema text file to find the error. Edit the text file, and run
the Schema Processor again.
MESSAGE BAD SUBITEM LENGTH OR TERMINATOR
MEANING Subitem length for data item defined in schema item is not an integer from
1 to 255.
ACTION Examine the schema text file to find the error. Edit the text file, and run
the Schema Processor again.
MESSAGE BAD TERMINATOR-';' EXPECTED
MEANING Password or capacity was not followed by a semicolon.
ACTION Examine the schema text file to find the error. Edit the text file, and run
the Schema Processor again.