TurboIMAGE/XL Database Management System Reference Manual (30391-90012)
Table Of Contents
- 1 Introduction
- 2 Database Structure and Protection
- 3 Defining a Database
- 4 Using the Database
- 5 TurboIMAGE/XL Library Procedures
- Using TurboIMAGE/XL Intrinsics
- DBBEGIN
- DBCLOSE
- DBCONTROL
- DBDELETE
- DBEND
- DBERROR
- DBEXPLAIN
- DBFIND
- DBGET
- DBINFO
- INTRINSIC NUMBER 402
- Syntax
- Parameters
- Discussion
- Mode 101: Item Number
- Mode 102: Item Name
- Mode 103: Items in Database
- Mode 104: Items in Data Set
- Mode 113: BTREEMODE1 and Wildcard Character
- Mode 201: Set Number
- Mode 202: Set Name
- Mode 203: Sets in Database
- Mode 204: Sets with Item
- Mode 205: Set Capacity
- Mode 206: Number of Data Set Chunks
- Mode 207: Size of Data Set Chunks
- Mode 208: Primary and Actual Capacity
- Mode 209: B-Tree Attachment
- Mode 301: Paths
- Mode 302: Key or Search Item
- Mode 401: Logging
- Mode 402: ILR
- Mode 403: Dynamic Roll-Back
- Mode 404: Logging Subsystem Information
- Mode 406: Database Information
- Mode 501: Subsystem Access
- Mode 502: Critical Item Update
- Modes 8nn: Third-Party Indexing
- Mode 901: Language
- DBLOCK
- DBMEMO
- DBOPEN
- DBPUT
- DBUNLOCK
- DBUPDATE
- DBXBEGIN
- DBXEND
- DBXUNDO
- 6 Host Language Access
- Model Program
- ORDERS Database Model Program
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- C
- COBOL II
- Defining Data Types, Variables, and Intrinsics
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- FORTRAN 77
- Pascal
- RPG
- 7 Logging and Recovery
- Database Utilities Used in Logging and Recovery
- Recovery Options
- Logical Transactions
- Dynamic Roll-Back Recovery
- Intrinsic Level Recovery
- Logging Preparation
- Step 1--Checking MPE/iX Logging Configuration
- Step 2--Acquiring Logging Capability
- Step 3--Logging to Tape or Disk
- Step 4--Building a Log File for Logging to Disk
- Step 5--Creating the Log Identifier
- Step 6--Setting the Log Identifier
- Step 7--Setting Flags for the Database Backup Copy
- Step 8--Making a Database Backup Copy
- TurboSTORE/iX 7x24 True-Online Backup
- Logging Status
- Logging Maintenance
- Roll-Forward Recovery
- Roll-Back Recovery
- DBRECOV Commands Used with Roll-Forward and Roll-Back Recovery
- Recovery Tables
- Post-Recovery Options
- The Mirror Database
- 8 Using the Database Utilities
- Restructuring the Database with TurboIMAGE/XL Utilities
- Summary of Utility Routines
- Utility Program Operation
- DBLOAD
- DBRECOV
- >CONTROL
- >EXIT
- >FILE
- >RECOVER
- >ROLLBACK
- >RUN
- DBRESTOR
- DBSTORE
- DBUNLOAD
- DBUTIL
- >>ACTIVATE
- >>ADDINDEX
- >>CREATE
- >>DEACTIVATE
- >>DETACH
- >>DISABLE
- >>DROPINDEX
- >>ENABLE
- >>ERASE
- >>EXIT
- >>HELP
- >>MOVE
- >>PURGE
- >>REBUILDINDEX
- >>REDO
- >>RELEASE
- >>SECURE
- >>SET
- >>SHOW
- Syntax
- Parameters
- Example (Show Users)
- Example Discussion
- Example (Show All)
- Example Discussion
- Example (Show Capacity)
- Format of Show Device List
- Example (Show Device)
- Format of Show Indices
- Example (Show Indices)
- Format of Show Locks List
- Example 1 (Show Locks)
- Example 1 Discussion
- Example 2 (Show Locks)
- Example 2 Discussion
- >>VERIFY
- 9 Using a Remote Database
- 10 Internal Structures and Techniques
- 11 B-Tree Indices
- A Error Messages
- B Results of Multiple Access
- C Database Design Considerations
- D Multiple Calls to DBLOCK
- E TurboIMAGE/XL Log Record Formats
- F MPE/iX Log Record Formats
- G Recovery and Logging Quick Reference
- H TurboIMAGE/XL versus TurboIMAGE/V

28 Chapter1
Introduction
Rapid Data Retrieval and Formatting
Rapid Data Retrieval and Formatting
Conventional file organization frequently requires using multiple file extracts, sorts, and
report programs to produce meaningful output. Information requests frequently require
weeks to implement, during which time the usefulness of the requested data can decrease.
QUERY/3000, the Hewlett-Packard database inquiry facility, or user-written inquiry
programs that use the TurboIMAGE/XL procedures, allow instant interrogation of the
database by individuals with access to the system. Other ad-hoc reporting packages are
also available.
Program Development
The database structure can be defined and built without using special purpose application
level programming. Because control of the linkage portion of the database is under
TurboIMAGE/XL software control, the programmer does not need to be concerned with
testing the structure and can concentrate on the functional programming task.
QUERY/3000 can be used to build test data, as well as to interrogate the results of
program and system tests. This feature eliminates the requirement that file-related
programs be completed before meaningful functional programs can be written. It is no
longer necessary to hold up functional program testing until file building or file
maintenance programs are completed. More modules of a given system can be tested at the
same time.
A specific benefit in the COBOL environment is program coding time. The programmer
need only define File Division entries for those files that exist outside the control of
TurboIMAGE/XL. Typically, such files are concerned with original entry into the
processing cycle (data entry files) and with report files. All data under the control of
TurboIMAGE/XL is implicitly defined in every program that accesses the database. The
programmer need not code the Data Division entries associated with anything except the
detail data used by a given program. The time savings generated in correct data definition
the first time the program is coded, as well as in the correct description of the physical
location of the data to be processed, will reap significant benefits in the program test cycle.