System Startup, Configuration, and Shutdown Reference Manual (32650-90907)
Appendix G
UPS and UPS Monitor/iX Software
Configuring a UPS Device
217
a. At the MPE prompt, start the sysgen program. Enter:
:SYSGEN CONFIG
b. Go into the IO menu and use the list device (LD) command to determine if the UPS device is
configured. Go go step c if the device does not exist or step d if it does exist but parameters are
incorrect.
io> ld 22
LDEV: 22 DEVNAME: OUTDEV: 22 MODE: JAID
ID: C1099A RSIZE: 40 DEVTYPE: TERM
PATH: 0/0/4/1.2 MPETYPE: 16 MPESUBTYPE: 0
CLASS: HPUPSDEV
NOTE The ID and PATH parameters will be different depending on the platform type.
c. If the device is not configured then execute the add device (AD) command to add the UPS ldev:
sysgen>io
io> ad 22 <ups path> <ID> class=HPUPSDEV
Where <ups path> and <ID> are taken from the table above.
d. If the device is configured but one or more parameters are incorrect, then execute the modify device
(MD) command to change the parameters to match those shown above.
io> md 22 id=<id> path=<ups path> class=hpupsdev
Where <id> and <ups path> are taken from the table above.
e. Verify that the ldev was configured correctly by executing the list path (LP) and list device (LD)
commands.
io> lp 0/0/4/1.2
PATH: 0/0/4/1.2 LDEV: 22
ID: C1099A TYPE: TERM
PMGR: CDM_CONSOLE_DM PMGRPRI: 9
LMGR: TIO_TLDM MAXIOS: 0
f. Verify that the HPUPSDEV device class name contains the UPS device:
io>lc hpupsdev
CLASSNAME MODE MIN MODE DCC MODE # DCC LDEV
--------- ------- -------- -------- ----- ----
HPUPSDEV default cio 0 22,