System Startup, Configuration, and Shutdown Reference Manual (32650-90892)

230 AppendixG
UPS and UPS Monitor/iX Software
Configuring a UPS Device
ID: c1099A RSIZE: 40 EVTYPE: TERM
PATH: 0/0/4/0.2 MPETYPE: 16 MPESUBTYPE: 0
CLASS: TERM
io>lp 0/0/4/0.2PATH: 0/0/4/0.2 LDEV: 22
ID: C1099A TYPE: TERM
PMGR: CDM_CONSOLE_DM PMGRPRI: 9
LMGR: TIO_TLDM MAXIOS: 0
c. Verify that the device class hpupsdev has been created. Use the list class (LC)
command to verify this:io> lc hpupsdev
CLASSNAME MODE MIN MODE DCC MODE # DCC LDEV
--------- ------- -------- -------- ----- ----
HPUPSDEV out out 0 22,
If the class doesn’t exist, then use the add class (AC) command to add it:
io> ac hpupsdev 22
If the class exists, but ldev 22 is not a member of that class, use the modify class
(MC) command to add ldev 22 to the class:
io> mc hpupsdev aldev=22
The path used above will be consistent always for A class systems. For N class
systems, this path will be used on the first release of the system core I/O board. A
later release of the core I/O 2 board will require the use of the following path to the
UPS port:
0/0/4/1.2
The path used above will be consistent always for A class systems. For N class
systems, this path will be used on the first release of the system core I/O board. A
later release of the core I/O 2 board will require the use of the following path to the
UPS port:
NOTE 0/0/4/1.2
3. At the MPE prompt, start the NMMGR program. Enter:
:RUN NMMGR.PUB.SYS