SNA NRJE User/Programmer Reference Manual (30292-90006)

208 Chapter6
NRJE Manager Intrinsics
NRJEUpdWel
NRJEUpdWel
Updates the NRJE subsystem welcome message.
Syntax
BA I IA
NRJEUpdWel (
Message
,
MessageLen
,
Result
)
Parameters
Message
An input byte array. The
Message
parameter
contains the message to be broadcast to any NRJE
subsystem command interpreter user. The maximum
Message
length is 1920 characters.
Separate each line of text by a carriage return
character and a line feed character. A carriage return is
%15, or !0D; a line feed is %12, or !0A.
MessageLen
An input integer. The
MessageLen
parameter
contains the length of the text in the
Message
array.
The maximum
MessageLen
value is 1920 characters.
Result
An eight-element integer output array (required).
The
Result
array contains error codes that occurred
during execution of this intrinsic.
The first element of the
Result
array is set to zero if no
errors took place. The structure of the
Result
array is
described in “Parameters Common to NRJE Intrinsics”
in the introduction to Chapter 5 , “User Intrinsics.
Always test the first element of
Result
immediately
after you call this intrinsic. If the first element of
Result
is not zero, test the other elements of
Result
to
determine the nature of the problem that has occurred.
Description
Use the NRJEUpdWel intrinsic to revise the whole NRJE subsystem
welcome message. The welcome message is broadcast every time any
user or manager enters the subsystem; however, it is not broadcast
when any user invokes the NRJE subsystem command to change from
one default workstation to another.
The text of the welcome message is input in
Message
. The length of the
welcome message text is input in
MessageLen
. After NRJEUpdWel
returns control to your program, test the first element of
Result
.