SNA NRJE Node Managers Guide (30292-90007)

Chapter 4 55
NA NRJE Workstation Startup and Shutdown
Starting a Workstation
Starting a Workstation
Once you have created the corresponding stream job files, you can start
up the workstations. To use an SNA NRJE workstation, you must
initiate an LU-LU session between an HP 3000 LU (the secondary LU)
and a host LU (the primary LU). An NRJE LU-LU session is initiated
by the LU in the HP 3000 node, with the MPE command NRJECONTROL
START or the NRJE command STARTWS (see Chapter 6 , “Commands,” of
this manual). The issued command causes an INITiate-SELF
(INIT-SELF) request to be sent to the SSCP.
In processing the INIT-SELF request, the SSCP determines if the host
LU is accepting session-initiation requests. The SSCP then sends a
Control INITiate (CINIT) request to the host LU. The host LU then
sends a BIND request to the HP 3000 LU. The BIND protocols specified
in the request must be accepted by the HP 3000. If the protocols are
acceptable, the HP 3000 LU sends a positive response, and the LU-LU
session is established. The host LU sends a SESSion STarted (SESSST)
request to notify the SSCP that the session has been established. The
host LU sends a Start Data Traffic (SDT) request to the HP 3000 LU, to
allow data requests to be transmitted. Figure 4-1 shows how an NRJE
LU-LU session is initiated.