SNA NRJE Node Managers Guide (30292-90007)
Chapter 3 25
SNA NRJE Configuration
Data Required From the Host Configuration
NOTE
If you are using JES2 version 1.3.6 (or later) or 2.1.5 (or later), the
&STDFORM parameter is different; use the migration tables to determine
the correct &STDFORM. For JES2 version 3 (or later), use COMPRESS=YES
instead of COMP.
Table 3-4 shows the relationship between items from the host
configuration and items in the NRJE configuration file.
Table 3-5 shows the relationship between items from the host
configuration and items in the NRJE configuration file.
Table 3-4 JES2 Macro Corresponding Values
Host Configuration Macro
and Parameter
Field in NMMGR Screen SNA NRJE NMMGR
Screen
LINE
nnn
PASSWORD
Line Password
Workstation Data
RMT
nnnn
Remote Node Number
Workstation Data
COMP or
COMPRESS=YES
Compression On
Reader Data
PASSWORD Term Password
Workstation Data
BUFSIZE Logical Unit RU Size
Workstation Data
NUMRD
Number of Readers
Reader Data
R
nnnn.
PR
m
Writer Name (PR
m
)
Writer List
New Name (PR
m
)
Writer List
PRWIDTH
MPE configured record size for
the default device (SYSDUMP).
none
R
nnnn
.PU
m Writer Name
(
PUm
)
Writer List
New Name (PU
m
)
Writer List
LRECL MPE configured record size for
the default device (SYSDUMP).
none