SNA NRJE Node Managers Guide (30292-90007)

Appendix A 237
Result Codes and Messages
SNA NRJE Logging Messages
9033 MESSAGE: NRJE(!:!): FPOINT FAILURE ON LOOKUP TABLE
(FSERR=!) (LU=9033)
CAUSE: A formid was found in the Lookup Table XDS but the applicable
record in the internal temporary copy of the Lookup Table could not be
referenced.
ACTION: Refer to the preceding message for a description of FSERR.
Contact Hewlett-Packard.
9034 MESSAGE: NRJE(!:!): WARNING: FAILED TO PARSE ‘ON READER’
MESSAGE: ! INVALID READER NUMBER DETECTED = !. (LU=9034)
CAUSE: NRJE received what looked like an “ON READER” message but
could not correctly identify the reader number in the message (valid
reader number range is 1 to 7). If an actual “ON READER” message
was received, then this reader will be unavailable for further job
submissions.
ACTION: If the message is in fact an “ON READER” message then
determine whether the format of the message has been modified by host
system programmers. If the message has not been modified, contact
Hewlett-Packard for assistance. If the message has been modified,
install an exit procedure to parse the message. Refer to the NRJE
User/Programmer Reference Manual for additional information.
9035 MESSAGE: NRJE(!:!): MEDIUM NOT PASSED TO GETWRITER.
(LU=9035)
CAUSE: GETWRITER was not passed a required parameter.
ACTION: Contact Hewlett-Packard.
9036 MESSAGE: NRJE(!:!): REQUIRED PARAMETERS NOT PASSED TO
SET'OUTPUT'PARMS (LU=9036)
CAUSE: FNUM or STATUS not passed to SET’OUTPUT’PARMS.
ACTION: Contact Hewlett-Packard.
9037 MESSAGE: NRJE(!:!): FAILED TO OPEN $NULL FILE (LU=9037)
CAUSE: A user wants to cancel his output, causing NRJE to route the
output to $NULL which could not be opened.
ACTION: Contact Hewlett-Packard.
9038 MESSAGE: NRJE(!:!): WARNING: USER ATTEMPTED TO ACCESS A
LOOKUP TABLE ENTRY WHEN THE LOOKUP TABLE WAS NOT IN
USE. JOBNUMBER=! USER ID = !. (LU=9038)
CAUSE: A user submitted a job specifying an alternate formid in the
Lookup Table (for example,SUBMIT
job
;FO='
formid
') but NRJE is not
configured to use a Lookup Table (Workstation Data screen).
ACTION: Contact the affected user.