SNA Link/iX Node Managers Guide (30291-90507)
Chapter 2 81
SNA Node and Link Configuration
Configuring the SNA Node and Link
to Table 2-10.
Use Factory-Configured Local Station Address
Enter Y to use the factory-configured local station
address. Enter N to use the address to be entered in the
Local Station Address field. In most IBM
environments, the local station address is assigned by
the IBM system manager. This is necessary since
connection establishment requires knowledge of remote
addresses.
NOTE
If the same Token Ring Card is being used for both NS and SNA
communications, you must specify the local station address that is
configured for the NS Token Ring Link.
Local Station Address
Required (if N is specified in the Use
Factory-Configured Local Station Address field.)
For non-AS/400 communications, HP recommends that
you use either the factory-configured address (enter Y
in the Use Factory-Configured Local Station
Address field) or use local station address for the NS
Token Ring Link, if it is configured.
AS/400 Configuration: The ADPTADR in the controller
description for the HP e3000 must match this field,
refer to Table 2-10.
NOTE
If the same Token Ring Card is being used for both NS and SNA
communications, you must use the local station address that is
configured for the NS Token Ring Link.
File:
For display only. The name of the configuration file.