SNA Link/iX Node Managers Guide (30291-90009)

Table Of Contents
Chapter 2 63
SNA Node and Link Configuration
Configuring the SNA Node and Link
Range: 1-999 (integer)
Default: 7
Transmission Speed
Required. The line transmission speed (bits per
second). This value is overridden by the modem, if one
is used. For direct-connect, the speed must be
supported by the cable.
Values: 1200 2400 4800 9600 19200 38400 56000
64000 (integer)
Default: 9600
Host Configuration: The SPEED operand of the LINE
macro must match this field; see Table 2-1.
AS/400 Configuration: The LINESPEED parameter in the
line description must match this field; see Table 2-7.
NRZI
Required. Enter Y to enable the Non-Return to Zero
Inverted (NRZI) feature; N to disable it (and enable
Non-Return to Zero [NRZ]).
Default: N
Host Configuration: The NRZI operand of the LINE
macro must match this field; see Table 2-1.
Station ID
Required. This defines the HP 3000’s link station
identifier to the remote system's communications
controller.
Range: 01-FE (hexadecimal)
Host Configuration: The ADDR operand of the PU macro
must match this field; see Table 2-1.
AS/400 Configuration: The
STNADR
parameter in the
controller description must match this field; see Table
2-7.
Auto Dial
Required. Enter Y only if you are using an auto-dial
modem and you want the modem to dial at link startup
time; N if a leased line, a manual-dial modem, or no
modem is used, or if you are using an auto-dial modem
but you want to defer dialing until the SNACONTROL
AUTODIAL command is issued (see Chapter 6 , “MPE
Commands.”)