MPE/iX Error Messages Manual Vol 2 (32650-90902)
304 Chapter8
System Startup, Shutdown, and Configuration
Class Errors
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
48 MESSAGE No message. System halts. (E)
CAUSE Test of load to status register fails.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
49 MESSAGE No message. System halts. (E)
CAUSE Test of instruction register fails.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
62 MESSAGE No message. System halts. (E)
CAUSE Detect failure of multiply chip U2302.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
64 MESSAGE No message. System halts. (E)
CAUSE Detect failure of add chip U2104.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
65 MESSAGE No message. System halts. (E)
CAUSE Detect failure of divide chip U2305.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
80 MESSAGE No message. System halts. (E)
CAUSE Detect failure in nullify generation circuitry.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
86 MESSAGE No message. System halts. (E)
CAUSE Microcode detects possible failure of RAM6 U1101.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
90 MESSAGE No message. System halts. (E)
CAUSE Microcode detects possible failure of RAM7 U1301.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
91 MESSAGE No message. System halts. (E)
CAUSE Microcode detects possible failure of RAM2 U1302.