MPE/iX Error Messages Manual Vol 2 (32650-90902)

252 Chapter7
Volume II Chapter 5
UPS
599 MESSAGE UPS Monitor warning: UPS Monitor process is
shutting down and restarting itself due to an
internal error condition. (UPSWRN 0599)
CAUSE The UPS Monitor detected an error condition internal to
its software, and is attempting to recover by restarting
itself from the beginning of its process.
ACTION If this warning appears only rarely, then no action is
needed. If it appears frequently, then call your
Hewlett-Packard service representative.
600 MESSAGE UPS Monitor error: UPS Monitor process is
shutting down, due to an unrecoverable
internal error condition. (UPSERR 0600)
CAUSE The UPS Monitor software detected an error condition
within its processing from which it can not recover.
Accordingly, it is shutting itself down, ending the UPS
monitoring processing.
ACTION This should rarely, if ever, happen in practice. You can
re-boot the system to see if the UPS Monitor will run
successfully after a new startup of the system. If the
problem persists, call your Hewlett-Packard service
representative.
601 MESSAGE UPS Monitor logic error: UPS Monitor process
unable to obtain list of UPS LDEVS from HLIO
after successfully obtaining number of UPS
devices from HLIO. (UPSERR 0601)
CAUSE This is a software-detected error condition that indicates
an error in the UPS Monitor software or in some other
system software, or a system memory error.
ACTION Call your Hewlett-Packard service representative.
602 MESSAGE UPS Monitor information: UPS Monitor process
startup of UPS devices failed, due to
inability to get UPS devices' allocation
information from the system. (UPSERR 0602)
CAUSE This is a software-detected error condition that indicates
an error in the UPS Monitor software or in some other
system software, or a system memory error.
ACTION Call your Hewlett-Packard service representative.