MPE/iX Error Messages Manual Vol 2 (32650-90902)

Chapter 4 143
Volume II Chapter 4
System Aborts
SWITCH_TO_CM.
1320 MESSAGE TIMER entry had an illegal state.
1321 MESSAGE The current process had no standard signal
port.
CAUSE GET_TIMEREQ: get_global_port_num returned no
number for the standard signal port.
1322 MESSAGE An invalid code was received from
compatibility TIMEREQ.
CAUSE GET_TIMEREQ: invalid timer code parameter received.
1323 MESSAGE Bad TABLE MANAGEMENT status was received when
the timer entry was released.
1324 MESSAGE The current process had no standard signal
port.
CAUSE PROC_PAUSE: get_global_port_num returned no number
for the standard signal port.
1325 MESSAGE The procedure INITIALIZE_TIMERS failed to
create TIMER ENTRY TABLE.
CAUSE The call to create_table failed.
1326 MESSAGE The procedure INITIALIZE_TIMERS failed to
create TIMER global area.
CAUSE The call to create_object failed.
1327 MESSAGE PDC TOD read failed.
CAUSE PDC_TIME: call to get_pdc_tod failed.
1328 MESSAGE PDC TOD write failed.
CAUSE SET_PDC_TIME: call to pdc_access_4 failed.
1329 MESSAGE Can not read PDC TOD calib.
CAUSE PDC_TIMER_CAL: call to get_pdc_timer failed.
1330 MESSAGE Can not read PDC TOD calib.
CAUSE PDC_TIMER_ACC: call to get_pdc_timer failed.
1331 MESSAGE CLOCK_SYNC WRITE failed.
CAUSE SYBC_CLOCKS: call to set_pdc_timer failed.
1332 MESSAGE The procedure failed to create port for clock
sync.
CAUSE INIT_HARDWARE_CLOCK_UPDATES: call to
create_port failed.
1333 MESSAGE The procedure failed to get TIMER for clock
sync.