MPE/iX Error Messages Manual Vol 2 (32650-90879)
256 Chapter7
Volume II Chapter 5
VolumeManagement
numbers are valid for the various volume specifier
numbers, consult the discussion for HPVOLINFO in the
MPE/iX Intrinsics Reference Manual.
177 MESSAGE HPVOLINFO RECEIVED AN ITEM NUMBER THAT HAS
NOT YET BEEN
IMPLEMENTED.(VLMERR 177)
CAUSE One of the item numbers passed to HPVOLINFO has not
been implemented yet.
ACTION Make sure all item numbers passed to HPVOLINFO are
implemented. To see which item numbers are
implemented, consult the discussion for HPVOLINFO in
the MPE/iX Intrinsics Reference Manual.
178 MESSAGE HPVOLINFO ENCOUNTERED A BAD VOLUME
TABLE.(VLMERR 178)
CAUSE This error should not be returned by HPVOLINFO
running on MPE/iX.
ACTION Call your HP Support Representative for assistance.
179 MESSAGE HPVOLINFO ENCOUNTERED AN UNRECOGNIZED DRIVE
TYPE.(VLMERR 179)
CAUSE This error should not be returned by HPVOLINFO
running on MPE/iX.
ACTION Call your HP Support Representative for assistance.
180 MESSAGE HPVOLINFO ENCOUNTERED A PHYSICAL I/O
ERROR.(VLMERR 180)
CAUSE The volume specified in the volume specifier was unable to
respond with the information requested by HPVOLINFO
due to a hardware failure.
ACTION Check to see if the volume is on-line, the power cables are
conneted and all cables are connected correctly. If the
problem persists, call your HP Support Representative for
assistance.
181 MESSAGE HPVOLINFO RECEIVED AN UNEXPECTED
ERROR.(VLMERR 181)
CAUSE HPVOLINFO received an unexpected error.
ACTION Check the error stack for your process to determine the
exact error and call your HP Support Representative for
assistance.
182 MESSAGE HPVOLINFO RECEIVED AN ERROR FROM THE LABEL
MANAGEMENT SUBSYSTEM.(VLMERR 182)
CAUSE An error was detected in the Label Managemant
Subsystem.