MPE/iX Error Messages Manual Vol 1 (32650-90878)

374 Chapter5
Error Messages V i C 5
(Subsystem 198)
the disk's REBUILD operation has not yet been
performed.
ACTION Use the FLEXDIAG diagnostic program to perform a
REBUILD operation on the disk device. After successful
REBUILDing, the mechanism that was being skipped will
no longer be skipped: it will be assigned to the striped
logical unit.
-179 MESSAGE CS80_STRIPED_XOR_ERROR A multi-mechanism disk
array device controller has detected an XOR
Error on a Read Data operation on a Striped
With Parity disk device. The parity computed
from the striped data did not match the
parity stored on the Data Protect disk.
CAUSE 1) Failure to properly format a Striped With Parity disk
device. 2) Reading data from an area of the disk media
that had not been completely written.
ACTION Call your Hewlett-Packard Representative.
-180 MESSAGE CS80_UNKNOWN_HW_STATUS_CLASS The hardware
status from the disk device could not be
recognized by the system software because the
value of the first byte of status (the
"status class") was not one of the legal
values defined for the device.
CAUSE Hardware problem in the disk device or in the cabling or
interfaces between the disk device and the host system.
ACTION Call your Hewlett-Packard Representative.
-181 MESSAGE CS80_UNKNOWN_HARDWARE_ERR The hardware status
from the disk device could not be recognized
by the system software because the value of
the second byte of status was not one of the
legal values defined for the Hardware Error
status class.
CAUSE Hardware problem in the disk device or in the cabling or
interfaces between the disk device and the host system.
ACTION Call your Hewlett-Packard Representative.
-182 MESSAGE CS80_UNKNOWN_RESOURCE_ERR The hardware status
from the disk device could not be recognized
by the system software because the value of
the second byte of status was not one of the
legal values defined for the Resource Error
status class.
CAUSE Hardware problem in the disk device or in the cabling or
interfaces between the disk device and the host system.