MPE/iX Error Messages Manual Vol 1 (32650-90878)
320 Chapter4
Error Messages V i C 4
(Subsystem 121)
14 MESSAGE The bit in the CS80 hardware status was set,
indicating that a LATENCY in the data
transfer occurred.
CAUSE Additional rotation of spindle needed.
ACTION None.
15 MESSAGE The bit in the CS80 hardware status was set,
indicating that only one spare track remains
on the disk.
CAUSE Excessive sparing has been necessary with this media.
ACTION Call your support representative.
16 MESSAGE The bit in the CS80 hardware status was set,
indicating that the device is requesting
release to perform head alignment. The DEVICE
MANAGER will grant.
CAUSE Automatic head alignment/diagnostics was performed.
ACTION None.
17 MESSAGE The bit in the CS80 Hardware status was set,
indicating that the diagnostic frontpanel was
manipulated causing a REQUEST for RELEASE.
CAUSE User activated front panel diagnostics.
ACTION Verify by looking at front panel.
18 MESSAGE The bit in the CS80 hardware status was set,
indicating that the operator button was
pushed, causing a REQUEST for RELEASE.
CAUSE User attempted to spin-down disk pack.
ACTION Either push button back in, or remove pack.
19 MESSAGE An error occurred previously which caused the
request to be RETRIED by the DEVICE MANAGER.
The retry was SUCCESSFUL.
CAUSE I/O was retried.
ACTION None.
20 MESSAGE The DOBIND was successful. However, the
DEVICE ADAPTER MANAGER is of an incorrect
revision.
CAUSE Software versioning problem.
ACTION Call your support representative.
21 MESSAGE The DOBIND was successful. However, the
initialization of hardware received a
TIMEOUT.