HP System Dictionary/XL General Reference Manual Vol 2 - Part 1 SDINIT (32256-90005)
2- 21
| 1 ALL |
| 2 Capacity for ALIASES is xxx |
| 3 Capacity for user defined ATTRIBUTES is xxx |
| 4 Capacity for user defined ENTITY TYPES is xxx |
| 5 Capacity for user defined RELATIONSHIP CLASSES is xxx |
| 6 Capacity for user defined binary RELATIONSHIP TYPES is xxx |
| 7 Capacity for user defined N-ary RELATIONSHIP TYPES is xxx |
| 8 Capacity for average no. attributes associated to ET & RT is xxx|
| 9 Capacity for DOMAINS is xxx |
| 10 Capacity for ENTITY names is xxx |
| 11 Capacity for total versions of ENTITIES is xxx |
| 12 Capacity for binary RELATIONSHIPS is xxx |
| 13 Capacity for N-ary RELATIONSHIPS is xxx |
| 14 Capacity for total versions of RELATIONSHIPS is xxx |
| 15 Capacity for FIXED LENGTH ATTRIBUTE DATA is xxx |
| 16 Capacity for FIXED LENGTH ATTRIBUTE EDIT DATA is xxx |
| 17 Capacity for VARIABLE LENGTH ATTRIBUTE DATA is xxx |
| 18 Capacity for SCOPES is xxx |
| 19 Capacity for SCOPE/ENTITY associations is xxx |
| 20 Capacity for SCOPE/RELATIONSHIP associations is xxx |
| 21 Capacity for SCOPE/DOMAIN associations is xxx |
| 22 Capacity for VERSIONS is xxx |
| 23 Capacity for VERSION LOGGING is xxx |
| 24 DONE |
| |
| Enter code > |
__________________________________________________________________________
As you did when initializing the dictionary, you are now free to change any of the capacities. You can alter
the capacity of any item by entering the appropriate code number next to that item. Valid responses are
code numbers 1 through 24, [[RETURN]], and [[CONTROL]] Y. Any other response will result in an error
and Enter code> will be reprompted.
• If you enter code 1, you will be prompted for a new capacity for each of the dictionary components. After
the last item is prompted, the entire capacity list is displayed, giving you another chance to verify its
correctness.
If you enter [[CONTROL]] Y while being prompted for the capacities, SDINIT will discontinue prompt-
ing and list the current capacities, allowing you to verify the list.
• If you enter any number from 2 to 23, you may alter a specific capacity. If, for example, you enter code
3, the prompt will be:
New Capacity for user defined ATTRIBUTES (xxx) >>
If you enter [[RETURN]] or [[CONTROL]] Y to this prompt, the default value will be used.
• The prompt Enter code > is repeated until a [[RETURN]], code 24, or [[CONTROL]] Y is entered. If any
of these responses are entered, the capacities are listed, allowing you to verify them.
Once all desired changes have been made, if the file SDTEMP1 already exists, you will be prompted for
permission to overwrite it as shown below.