HP System Dictionary/XL General Reference Manual Vol 2 - Part 1 SDINIT (32256-90005)
2- 19
DBSTORE program which resides in the PUB group of the SYS account. Therefore, in the event that some
problem occurs during reinitialization, you have a complete back of the current dictionary. Refer to the
TurboIMAGE Reference Manual for detailed instructions for running DBSTORE. Once the database is
stored, you must choose the Reinitialization option in response to the following prompt in order to
reinitialize the dictionary:
Initialization / Reinitialization (I/R) >
The Dictionary Password
Before you can begin reinitializing the dictionary, you must supply the dictionary database password. This
is the password which the dictionary was given at initialization time. If you enter [[RETURN]] or if you
make a mistake when entering the old password, you will be reprompted. If you do not enter the correct
password after being prompted three times, SDINIT automatically terminates. For security reasons, the
echo will be turned off for the response to the password prompts:
Dictionary database old password >
Once the correct old password is entered, the next prompt that appears allows you to change the dictionary
database password:
Dictionary database new password >
Verification of new password >
If you enter [[RETURN]] in response to the new password prompt, the old password will be used. If you
enter a new password and do not type in the same password at the Verification of new password > prompt,
the following message will appear and you will again be prompted for the new password and verification:
Verification of password failed (SDERR 2205)
The next prompt that appears allows you to change the capacities.
Change dictionary capacities? (N/Y) >
If you want to change the existing capacities , enter "Y", and follow the steps under the heading "New
Capacities" (next page).
If you have changed the existing password, but want to keep the existing capacities, enter "N" or
[[RETURN]], and follow the steps under the heading "Current Capacities" (next page).
Current Capacities. At this point, if either of the files named SDTEMP1 or SDTEMP2 exists, you will
be prompted for permission to overwrite them.
SDTEMP1.groupname.accountname already exists. Is it okay to overwrite (N/Y)?
SDTEMP2.groupname.accountname already exists. Is it okay to overwrite (N/Y)?
If you answer "N" to either of these prompts, SDINIT will terminate, and the password will not be
changed.
If you answer "Y" to both of these prompts, the password will be changed, and no further user interaction
will be required.
New Capacities. At this point, if the file SDPASS already exists, you will then be prompted for
permission to overwrite.
SDPASS.groupname.accountname already exists. Is it okay to overwrite (N/Y)?
If you answer "N" to this prompt, SDINIT will terminate.
The next prompt that appears allows you to specify where the current dictionary contents will be stored