HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)

Chapter 6
Finishing the Process
6.9 Backing Up Your System
156
6.9 Backing Up Your System
To back up the system.
1. Mount a write-enabled tape to create a backup SLT.
:SYSGEN
sysgen>TAPE
sysgen>EXIT
2. Dismount the tape, label as SLT with date, time and system version.
3. We recommend that you stop running the STM diagnostics daemon in order to back up the files associated
with it. To do this, run the STMSHUT.DIAG.SYS program.
:stmshut.diag.sys
diagmond has been stopped
4. Mount another blank tape and perform a full system backup.
:FILE T;DEV=TAPE
:STORE /;*T;DIRECTORY;SHOW
5. Dismount the tape, label as backup with date, time and system version.
6. Restart the STM daemons by running the STMSTART.DIAG.SYS program.
:stmstart.diag.sys
STM Diagnostic Monitor already stopped.
diagmond has been started
Please wait a few minutes for diagmond to complete initialization
STM system manager started
Backing Up Your System completed. Go to the next section on your checklist.