5.12 Shutting Down the Remote System
128
5.12 Shutting Down the Remote System
To shut down the remote system:
1. Log onto the remote system console.
:HELLO MANAGER.SYS,INSTALL;HIPRI
:SPOOLER LP;START
:STREAMS streams_device
A common streams_device value is 10. An LP device must be configured in SYSGEN. Already spooled and
streamed messages might display.
2. Shutdown the system.
CTRL-A
=SHUTDOWN
3. Reset the system after the last shutdown message (SHUT6).
a. If you have an HP e3000 Series 99x, connect to the service processor before you can restart the
system. Type the following:
CTRL-B
CM>SP
SP>RS
Enter Y to HARD BOOT the computer system.
Do not respond to the question:
Press any key within 10 seconds to cancel boot with this
configuration.
There are 5 to 10 minutes of system activity, then the Processor Dependent Code (PDC) screen
displays.
b. For HP e3000 N-Class, A-Class
CTRL-B
Service Processor login:
Service Processor password:
If you get the following prompt, then enter the characters ‘Ctrl-E c fto gain write access to the GSP.
[Read only - use ^Ecf for console write access.]
GSP>RS
c. For all other systems, enter the following commands to reset the system:
CTRL-B
CM>RS
If the system does not respond to the CTRL-B entry within ten seconds, press the reset button, key
switch, or on/off switch as appropriate for your system. The system will halt, and then restart
automatically.
Enter Y to confirm restarting the system.
Shutting Down the Remote System completed. Go to the next section on your checklist.