HP e3000 MPE/iX Release 7.0 System Software Maintenance Manual (30216-90317)
Appendix H 387
Error Messages and Warnings
Installer Error Messages (INSTERR)
installer again.
• Contact the Response Center if further assistance is
required.
98 Message The installer encountered an error while
monitoring
a streamed job. Error status returned by JobInfo
intrinsic: status
. (INSTERR #98)
Cause A call to the JOBINFO intrinsic failed while the installer
was attempting to obtain the number of a given job name
or to obtain the state of a job. The job in question should be
the last job streamed.
Action • If the USL, UXL, UNL groups were not purged prior to
starting the installation, purge them and restart the
installation procedures.
• Check the last streamed job's spoolfile, if it exists. The
jobs streamed by the installer are listed in the
HPINSTFL.INSTALL.SYS file.
• Ensure the spooler has been started for the LP device.
• Type LISTF I???????.USL.SYS.
• If the file INDIRECT.USL.SYS exists, purge it, and run
the installer again.
• Determine the current job from the HPINSTFL file and
check the JOB's existence and/or termination.
• If the ifilename identified by HPINSTFL exists, inspect
that file for valid job commands. If this inspection
shows that the file is not a valid job, either purge the
file, or remove it from the USL.SYS group.
• If the ifilename identified by HPINSTFL exists and
inspection of the file shows that the file is a valid job,
the file may be corrupted. Purge the file, and restore it
again from the SUBSYS tape.
• Take appropriate corrective measures and run the
installer again.
• Contact the Response Center if further assistance is
required.
99 Message Corrupt filename file. (INSTERR #99)
Cause Format of filename is unusable by the installer. Each line
should be a proper file equation format.
Action • If the filename is SLTFEQ, purge SLTFEQ and
HPINSTFL files.