HP e3000 MPE/iX Release 7.0 System Software Maintenance Manual (30216-90317)
Appendix H 349
Error Messages and Warnings
SETUP Error Messages (SETERR)
SETUP will terminate. Follow the instructions in
your installation manual to continue. (SETERR
#29)
Cause A INITCIVR existed from a previous execution of
SETUP.INSTUTIL, and it could not be purged.
Action • Ensure that the file is not busy.
• Ensure that the file is not a temporary file.
• Purge INITCIVR.
• Execute SETUP.INSTUTIL.
• Contact the Response Center if further assistance is
required.
30 Message Unable to set file equation for data file,
INITCIVR.
SETUP will terminate. Follow the instructions in
your installation manual to continue. (SETERR
#30)
Cause SETUP.INSTUTIL failed when attempting to set a file
equation for INITCIVR.
Action • Do a LISTEQ to determine which file equations have
been set.
• Reset the files for which you no longer need file
equations. (If no file equations are needed, do a RESET
@.)
• Contact the Response Center if further assistance is
required.
31 Message Unable to purge old initialization file,
SETUPYES.
SETUP will terminate. Follow the instructions in
your installation manual to continue. (SETERR
#31)
Cause A SETUPYES existed from a previous execution of
SETUP.INSTUTIL, and it could not be purged.
Action • Ensure that the file is not busy.
• Ensure that the file is not a temporary file.
• Purge SETUPYES.
• Execute SETUP.INSTUTIL.
• Contact the Response Center if further assistance is
required.
32 Message Unable to purge old initialization file,
SETINIT. SETUP will terminate. Follow the