High Availability FailOver/iX Manual (32650-90911)
Configuration
GONEXT (go)
GONEXT (go)
The
GONEXT
command causes the Ldev to switch from the current, “Ready”,
path to the “Validated” path according to the HAFOCONF file.
The most important use of this command is after the repair of a “failed” primary
path.
GONEXT
switchs the Ldev from using the alternate path back to using the
primary path. GONEXT
can also be used during preventative maintenance
activities to temporarily switch from the primary path to the alternate path. This
command is fully documented in Chapter 6, "Recovering From a Failure."
WARNING
HAFO protection is only available on the primary path! Use the
GONEXT
command to switch to the alternate path with caution. You should never
intentionally run your system using the alternate path for extended periods of
time.
WARNING
GONEXT
should NOT be used to “force” HAFO to use a known bad path for any
reason. Attempts to force usage of a “broken” path may result in the need to do a
full System Reboot to reinitialize the MPE/iX I/O configuration.
29