Configuring Systems for Terminals, Printers, and Other Serial Devices (32022-90051)
Appendix D 229
Error Messages
Validation Error Messages
Path: NMMGRpath — Modem behavior DCE high for LDEV #nnn,
defined in Profile profilename, is not supported on DTC16 and DTC48.
(DTSERR=71)
(DTSERR 71) Cause: DCE high modem behavior is not supported for devices on a
DTC 16 or DTC 48. DCE high is being specified for LDEV #nnn, which
is on a DTC 16 or DTC 48.
Action: Modify the modem behavior to one that is supported for the
DTC, or make sure you have specified the right DTC type (not a DTC 16
or DTC 48) for the device with LDEV #nnn.
Path: NMMGRpath — Hardware handshaking for LDEV #nnn, defined
in Profile profilename, is not supported on DTC16 and DTC48.
(DTSERR=72)
(DTSERR 72) Cause: Hardware handshaking is not supported for devices on a
DTC 16 or DTC 48. Hardware handshaking is being specified for LDEV
#nnn, which is on a DTC 16 or DTC 48.
Action: Make sure you have specified the right DTC type (not a
DTC 16 or DTC 48), or if you are configuring ports on a DTC 16 or
DTC 48, do not use a profile that specifies hardware handshaking.
Path: NMMGRpath — Modem behavior is not supported.
(DTSERR=73)
(DTSERR 73) Cause: An invalid modem behavior has been specified. Valid modem
behavior values are: 0, 1, 2, or 3. The configuration file may be corrupt.
Action: Modify the modem behavior specified on the Terminal Profile
or Printer Profile screens to a valid value.
Path: NMMGRpath — Invalid AFCP timer selection. (DTSERR=74)
(DTSERR 74) Cause: You have specified an invalid AFCP timer selection.
Action: Go to the Tune DTC — Timer Selection Screen and choose a
value from 1 to 6 for an AFCP timer selection.
Path: NMMGRpath — Invalid Management timer selection.
(DTSERR=75)
(DTSERR 75) Cause: You have specified an invalid management timer selection.
Action: Go to the Tune DTC — Timer Selection Screen and choose a
value of 1 or 2 for a management timer selection.
Path: NMMGRpath — Baud rate 38400 for LDEV #nnn, defined in
Profile profilename, is not supported on DTC16 and DTC48.
(DTSERR=76)
(DTSERR 76) Cause: You have used a profile that specified a baud rate of 38400 for a
device that is connected to a DTC 16 or DTC 48.
Action: Make sure you specified the right DTC type (not a DTC 16 or
DTC 48), or do not use this profile for the port with LDEV #nnn.