86 Chapter4
APPC Subsystem Configuration
Configuring the APPC Subsystem
If parallel sessions are disabled (Parallel Sessions =
N), the Maximum Number of Sessions value must be 1.
If parallel sessions are enabled (Parallel Sessions =
Y), the following restrictions apply to the Maximum
Number of Sessions value:
1. The maximum number of simultaneously active
sessions for an independent session type is 256.
2. The maximum number of simultaneously active
sessions for the whole APPC subsystem is 256.
3. Maximum Number of Sessions must be greater
than or equal to the Automatically Activated
Sessions value
If parallel sessions are enabled, the Maximum Number
of Sessions value might be negotiated at session
activation time.
Default: 8
Automatically Activated Sessions
Required. The number of sessions that will be
activated automatically when the APPCCONTROL
START command is issued or the APPCStart intrinsic
is called. The Automatically Activated Sessions
value must be less than or equal to the value in the
Maximum Number of Sessions field. The sum of the
Automatically Activated Sessions values for all
the session types on the APPC subsystem must not
exceed 256.
Default: 0
Figure 4-8 shows possible and impossible configurations for
independent LUs on the HP 3000. The dotted lines in Figure 4-8
represent APPC sessions.
Possible configurations: An independent LU on the HP 3000 can
communicate with multiple remote independent LUs, as long as all the
routes to the remote LUs pass through the same PSI card (the same
copy of SNA/SDLC Link/XL) on the HP 3000. The remote LUs can be on
the same node, or they can be on nodes connected to a Network Node
that is directly connected to the HP 3000.
Impossible configurations: An independent LU on the HP 3000
cannot communicate with multiple remote independent LUs if they are
connected to the HP 3000 through different SNA nodes (different PSI
cards). To communicate with multiple remote LUs that are connected to
the HP 3000 through different PSI cards, you must configure different
independent LUs on the HP 3000.