APPC Subsystem on MPE/XL Node Manager's Guide (30294-90007)
Appendix A 175
Messages
Return Codes
-1051 MESSAGE: CNOS TP detected error during subsystem start-up
CAUSE: Internal error in APPC subsystem.
ACTION: Contact your HP representative.
-1063 MESSAGE: Resource Manager error — CHANGE_SESSIONS_FAILED
CAUSE: The APPC subsystem detected an internal error.
ACTION: Call your HP representative.
-1064 MESSAGE: Resource Manager error — subsystem shutdown failed
CAUSE: Internal error in APPC subsystem.
ACTION: Call your HP representative.
-1065 MESSAGE: Control operator internal error
CAUSE: Internal error in APPC subsystem.
ACTION: No action required.
-1066 MESSAGE: APPC object access error
CAUSE: The Control Operator TP was unable to access the APPC KSO.
ACTION: Call your HP representative.
-1072 MESSAGE: APPC subsystem not active
CAUSE: The intrinsic called cannot be executed because the APPC
subsystem was not started.
ACTION: Start the APPC subsystem with the APPCCONTROL START
command before running your program, or code your program to call
the APPCStart intrinsic before calling any other APPC intrinsics.
-1073 MESSAGE: APPC subsystem pending active
CAUSE: The intrinsic called cannot be executed because the APPC
subsystem startup is in progress.
ACTION: Check the status of the APPC subsystem and restart your
program when the subsystem is active. If problems still exist, call your
HP representative.
-1074 MESSAGE: APPC subsystem already active
CAUSE: The APPCStart intrinsic was called after the APPC subsystem
had already been activated.
ACTION: No action necessary.
-1075 MESSAGE: APPC subsystem shutting down
CAUSE: A control operator intrinsic was called after initiation of
subsystem shutdown.