8-port Serial PCI ACC Multiplexer Installation & Service Guide (30291-90508)
Chapter 3 27
Configuration
Configuration of Clock Source Using NMMGR
3 Configuration
Configuration of Clock Source Using NMMGR
Refer to Table 3-1 to configure the clock source parameter using
NMMGR:
1. Direct Connect (2 ACC — connected back-to-back using loopback
cable).
2. Connected to MODEM (or External DCE device).
3. Direct Connect (ACC and PSI connected back-to-back using loopback
cable).
NOTE Auto dial is not supported on ACC (outbound Dial is not supported, but
inbound connections are supported). Configure Modem Type to 0
(which is leased or Direct Connect).
When the WAN port is externally connected to the DCE (like a modem)
which provides an external clock, then configure Clock source as
External.
When connecting ACC on one system to ACC on other systems using a
loopback cable (Null Modem):
• Clock source in one system should be configured for 1 (External
clocking) and another should be connected for 0 (internal clocking).
• When connecting ACC on one system to a PSI on a different system
(using loopback cable), always configure Clock source on the ACC
port to the internal clocking.
• Local Mode in one should be 6 (DCE) and another one must be 5
(DTE).
The configured clock of each port must match the corresponding end of
the loopback cable. The end of the cable labeled internal goes to the side
configured as internal clocking.