Using the Node Management Services (NMS) Utilities (MPE/iX 7.0, 7.5)
Appendix A 285
NMS Error Messages
NMMGRVER Messages, Errors and Warnings
NMMGRVERERR
85
MESSAGE: An error has occurred during NETXPORT CONVERSION.
(NMMGRVERERR 85)
CAUSE: An error occurred during the NETXPORT part of the
conversion process. The actual error is listed in an error message which
should be displayed along with this one.
ACTION: Restore a backup copy of the configuration file if possible. Use
the version of NMMGR that created the configuration file to make sure
that each data screen in the configuration file has data associated with
it and that its data flag is set to Y. Run NMMGRVER again. If the same
error occurs again, check any accompanying error message and take the
action listed for it in this appendix. If this fails, submit a Change
Request. See “Submitting a CR” at the beginning of this appendix.
NMMGRVERERR
86
MESSAGE: An error has occurred during LAPB LINK CONVERSION.
(NMMGRVERERR 86)
CAUSE: An error occurred during the LAPB LINK part of the conversion
process. The actual error is listed in an error message which should be
displayed along with this one.
ACTION: Restore a backup copy of the configuration file if possible. Use
the version of NMMGR that created the configuration file to make sure
that each data screen in the configuration file has data associated with
it and that its data flag is set to Y. Run NMMGRVER again. If the same
error occurs again, check any accompanying error message and take the
action listed for it in this appendix. If this fails, submit a Change
Request. See “Submitting a CR” at the beginning of this appendix.
NMMGRVERERR
87
MESSAGE: An error has occurred during DTS CONVERSION.
(NMMGRVERERR 87)
CAUSE: An error occurred during the DTS part of the conversion
process. The actual error is listed in an error message which should be
displayed along with this one.
ACTION: Restore a backup copy of the configuration file if possible. Use
the version of NMMGR that created the configuration file to make sure
that each data screen in the configuration file has data associated with
it and that its data flag is set to Y. Run NMMGRVER again. If the same
error occurs again, check any accompanying error message and take the
action listed for it in this appendix. If this fails, submit a Change
Request. See “Submitting a CR” at the beginning of this appendix.
NMMGRVERERR
88
MESSAGE: An error has occurred during LAN LINK CONVERSION.
(NMMGRVERERR 88)
CAUSE: An error occurred during the LAN LINK part of the conversion
process. The actual error is listed in an error message which should be
displayed along with this one.
ACTION: Restore a backup copy of the configuration file if possible. Use
the version of NMMGR that created the configuration file to make sure