Using the Node Management Services (NMS) Utilities (MPE/iX 7.0, 7.5)

274 AppendixA
NMS Error Messages
NMMGRVER Messages, Errors and Warnings
NMMGRVER
WARN 3
MESSAGE: INTERNAL ERROR: cannot convert file.
(NMMGRVERWARN 3)
CAUSE: The configuration file is corrupted. One or more of the following
situations were detected in the file.
Paths are missing.
Version stamps are missing or are incorrect.
A LINKCONF detail data record has unexpected record length.
NOTE: This corrupted configuration file is not changed.
ACTION: Restore an old configuration file if possible and rerun
NMMGRVER. If the error still occurs, see “Submitting a CR” at the
beginning of this appendix.
NMMGRVERERR
4
MESSAGE: FILE CORRUPT: Conversion Failed, file might be changed.
(NMMGRVERERR 4).
CAUSE: NMMGRVER was unable to complete the configuration file
conversion because a LINKCONF detail data record has the incorrect
item identification number. Note: The configuration file may have been
changed.
ACTION: The configuration file may be corrupted. Restore a backup
copy of the configuration file if possible and run NMMGRVER again. If
the error still occurs, submit a Change Request. See “Submitting a CR”
at the beginning of this appendix.
CAUSE: NMMGRVER was unable to complete the configuration file
conversion because a data record has incorrect record length.
ACTION: The configuration file may be corrupted. Restore a backup
copy of the configuration file if possible and run NMMGRVER again. If
the error still occurs, submit a Change Request. See “Submitting a CR”
at the beginning of this appendix.
CAUSE: NRJE has the wrong previous version stamp. Note that the
configuration file may have been changed.
ACTION: The configuration file may be corrupted. Restore a backup
copy of the configuration file if possible and run NMMGRVER again. If
the error still occurs, submit a Change Request. See “Submitting a CR”
at the beginning of this appendix.
NMMGRVERERR
5
MESSAGE: INTERNAL ERROR: Conversion Failed, file might be
changed. (NMMGRVERERR 5).
CAUSE: Disk file space is used up.
ACTION: Purge unnecessary files from disk to recover some space.
Restore a backup copy of the configuration file if possible and run
NMMGRVER again. If the error still occurs, submit a Change Request.
See “Submitting a CR” at the beginning of this appendix.