TurboIMAGE/XL Database Management System Reference Manual (30391-90012)
Table Of Contents
- 1 Introduction
- 2 Database Structure and Protection
- 3 Defining a Database
- 4 Using the Database
- 5 TurboIMAGE/XL Library Procedures
- Using TurboIMAGE/XL Intrinsics
- DBBEGIN
- DBCLOSE
- DBCONTROL
- DBDELETE
- DBEND
- DBERROR
- DBEXPLAIN
- DBFIND
- DBGET
- DBINFO
- INTRINSIC NUMBER 402
- Syntax
- Parameters
- Discussion
- Mode 101: Item Number
- Mode 102: Item Name
- Mode 103: Items in Database
- Mode 104: Items in Data Set
- Mode 113: BTREEMODE1 and Wildcard Character
- Mode 201: Set Number
- Mode 202: Set Name
- Mode 203: Sets in Database
- Mode 204: Sets with Item
- Mode 205: Set Capacity
- Mode 206: Number of Data Set Chunks
- Mode 207: Size of Data Set Chunks
- Mode 208: Primary and Actual Capacity
- Mode 209: B-Tree Attachment
- Mode 301: Paths
- Mode 302: Key or Search Item
- Mode 401: Logging
- Mode 402: ILR
- Mode 403: Dynamic Roll-Back
- Mode 404: Logging Subsystem Information
- Mode 406: Database Information
- Mode 501: Subsystem Access
- Mode 502: Critical Item Update
- Modes 8nn: Third-Party Indexing
- Mode 901: Language
- DBLOCK
- DBMEMO
- DBOPEN
- DBPUT
- DBUNLOCK
- DBUPDATE
- DBXBEGIN
- DBXEND
- DBXUNDO
- 6 Host Language Access
- Model Program
- ORDERS Database Model Program
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- C
- COBOL II
- Defining Data Types, Variables, and Intrinsics
- Main Body of Program
- Opening the Database
- Retrieving All the Records on a Chain (with Item Level Locking)
- Retrieving a Data Entry Using a Record Number
- Retrieving Master Data Using a Key Value
- Retrieving Data Serially (with Set Level Locking)
- Adding an Entry
- Updating an Entry
- Deleting an Entry
- Rewinding a Data Set
- Obtaining Database Information
- Obtaining Error Messages and Explanations
- Closing the Database
- FORTRAN 77
- Pascal
- RPG
- 7 Logging and Recovery
- Database Utilities Used in Logging and Recovery
- Recovery Options
- Logical Transactions
- Dynamic Roll-Back Recovery
- Intrinsic Level Recovery
- Logging Preparation
- Step 1--Checking MPE/iX Logging Configuration
- Step 2--Acquiring Logging Capability
- Step 3--Logging to Tape or Disk
- Step 4--Building a Log File for Logging to Disk
- Step 5--Creating the Log Identifier
- Step 6--Setting the Log Identifier
- Step 7--Setting Flags for the Database Backup Copy
- Step 8--Making a Database Backup Copy
- TurboSTORE/iX 7x24 True-Online Backup
- Logging Status
- Logging Maintenance
- Roll-Forward Recovery
- Roll-Back Recovery
- DBRECOV Commands Used with Roll-Forward and Roll-Back Recovery
- Recovery Tables
- Post-Recovery Options
- The Mirror Database
- 8 Using the Database Utilities
- Restructuring the Database with TurboIMAGE/XL Utilities
- Summary of Utility Routines
- Utility Program Operation
- DBLOAD
- DBRECOV
- >CONTROL
- >EXIT
- >FILE
- >RECOVER
- >ROLLBACK
- >RUN
- DBRESTOR
- DBSTORE
- DBUNLOAD
- DBUTIL
- >>ACTIVATE
- >>ADDINDEX
- >>CREATE
- >>DEACTIVATE
- >>DETACH
- >>DISABLE
- >>DROPINDEX
- >>ENABLE
- >>ERASE
- >>EXIT
- >>HELP
- >>MOVE
- >>PURGE
- >>REBUILDINDEX
- >>REDO
- >>RELEASE
- >>SECURE
- >>SET
- >>SHOW
- Syntax
- Parameters
- Example (Show Users)
- Example Discussion
- Example (Show All)
- Example Discussion
- Example (Show Capacity)
- Format of Show Device List
- Example (Show Device)
- Format of Show Indices
- Example (Show Indices)
- Format of Show Locks List
- Example 1 (Show Locks)
- Example 1 Discussion
- Example 2 (Show Locks)
- Example 2 Discussion
- >>VERIFY
- 9 Using a Remote Database
- 10 Internal Structures and Techniques
- 11 B-Tree Indices
- A Error Messages
- B Results of Multiple Access
- C Database Design Considerations
- D Multiple Calls to DBLOCK
- E TurboIMAGE/XL Log Record Formats
- F MPE/iX Log Record Formats
- G Recovery and Logging Quick Reference
- H TurboIMAGE/XL versus TurboIMAGE/V

Chapter 5 163
TurboIMAGE/XL Library Procedures
DBERROR
-11 BAD DATABASE NAME OR PRECEDING BLANKS MISSING
BAD DATABASE REFERENCE (FIRST 2 CHARACTERS)
-12 DATABASE MUST BE IN LOGON GROUP AND ACCOUNT
intrinsic name
CALLED WITHOUT COVERING LOCK IN EFFECT
-13 NOT ALLOWED; MUST BE CREATOR OF ROOT FILE OR DATABASE
-14 CALLS TO
intrinsic name
NOT ALLOWED IN ACCESS MODE
decimal
integer
-15 DSLINE OR REMOTE HELLO FAILURE: SETUP FOR RDBA FAILED
-21 BAD PASSWORD - GRANTS ACCESS TO NOTHING
DATA ITEM NONEXISTENT OR INACCESSIBLE
SPECIFIED INTRINSIC CANNOT ACCESS THE DATA SET
DATA SET NONEXISTENT OR INACCESSIBLE
BAD MAINTENANCE WORD (CONTAINS COMMA OR DOES NOT MATCH) ILLEGAL
NUMBER OF BUFFERS REQUESTED
-22 MAINTENANCE WORD REQUIRED
-23 USER (CLASS) LACKS WRITE ACCESS TO DATA SET
-24 OPERATION NOT ALLOWED ON AUTOMATIC MASTER DATA SET
-30 MPE V ILR ENABLED; ONLY DBOPEN (MODE 1-8) AND DBUTIL
DISABLE ILR ALLOWED
-31 DBGET MODE
decimal integer
ILLEGAL FOR DETAIL DATA SET
DBGET MODE
decimal integer
BAD--SPECIFIED DATA SET LACKS CHAINS
BAD (UNRECOGNIZED)
intrinsic name
MODE:
decimal integer
-32 UNOBTAINABLE ACCESS MODE: AOPTIONS REQUESTED:
%octal integer
,
GRANTED:
%octal integer
-33 MODE 7 DIAGNOSTICS NOT ALLOWED
-34 DATABASE MUST BE RECOVERED BEFORE ACCESS IS ALLOWED.
-51 LIST TOO LONG OR NOT PROPERLY TERMINATED
-52 ITEM SPECIFIED IS NOT AN ACCESSIBLE SEARCH ITEM IN THE
SPECIFIED SET
BAD LIST - CONTAINS ILLEGAL OR DUPLICATED DATA ITEM REFERENCE
-53 DBPUT LIST IS MISSING A SEARCH OR SORT ITEM
-60 ILLEGAL FILE EQUATION FOR ROOT FILE
-61 ERROR WHILE OBTAINING INFORMATION ABOUT FILE EQUATION.
-80 OUTPUT DEFERRED NOT ALLOWED WITH ILR ENABLED
-81 OUTPUT DEFERRED NOT ALLOWED WITH ROLLBACK ENABLED
Table 5-10. DBERROR Messages
Return Status DBERROR Message