Troubleshooting Terminal, Printer, and Serial Device Connections - Edition 5 (32022-90058)
TermDSM Messages
Appendix A
106
For example, to execute a DUmp command for an SNP card contained in slot 3 of the DTC
designated as DTC #1, you would enter the following subcommand at the DUmp
subcommand prompt:
SN 1,3
(TDSM 606) MESSAGE: You have entered a bad VC number. VC numbers range from 0 to 4095.
(TDSM 606)
CAUSE: The user entered an invalid number when asked to specify the VC number
associated with the virtual circuit on which the TermDSM function is to be performed.
ACTION: Enter the number that corresponds to the VC on which the TermDSM function
is to be performed. Valid numbers range from 0 to 4095.
(TDSM 607) MESSAGE: The VC number is missing or invalid. VC numbers range from 0 to 4095.
(TDSM 607)
CAUSE: The user entered a TermDSM subcommand specifying the VC option but did not
specify a valid VC (virtual circuit) number.
ACTION: Reenter the subcommand specifying a valid VC number. Virtual circuits may be
numbered from 0 through 4095.
For example, to execute a DUmp command for VC #15 active on an SNP card in slot 3 of
DTC #1, you would enter the following subcommand at the DUmp subcommand prompt:
V 1,3,15
(TDSM 608) MESSAGE: You have entered an invalid X25 address. The X25 address may be up to 15
digits from 0 to 9. (TDSM 608)
CAUSE: The user entered an invalid X.25 address during execution of the XNetwork
subcommand of the DIag function of TermDSM.
ACTION: Determine the correct X.25 destination address as configured on the Level 3
Configuration screen in NMMGR. Reenter the XNetwork subcommand using the correct
X.25 address.
For example, to perform a loopback for an SNP card contained in slot 3 of the DTC
designated as DTC #1, with a destination address configured as 345678, you would enter
the following subcommand at the DIag subcommand prompt:
XN 1,3,345678
(TDSM 609) MESSAGE: The X25 address is missing or invalid. The X25 address may be up to 15
digits from 0 to 9. (TDSM 609)
CAUSE: The user failed to enter a valid X.25 address during execution of the XNetwork
subcommand of the DIag function of TermDSM.
ACTION: Determine the correct X.25 destination address as configured on the Level 3
Configuration screen in NMMGR. Reenter the XNetwork subcommand using the correct
X.25 address.
For example, to perform a loopback for an SNP card contained in slot 3 of the DTC
designated as DTC #1, with a destination address configured as 345678, you would enter
the following subcommand at the DIag subcommand prompt:
XN 1,3,345678
(TDSM 610) MESSAGE: You have entered a bad X25 status option. X25 status options range from 1
to 4. (TDSM 610)