System Startup, Configuration, and Shutdown Reference Manual (32650-90907)

Chapter 7
Modifying Miscellaneous Configuration Elements
Setting Strings and String Parameters
148
Setting Strings and String Parameters
The SYSTEM command (abbreviated SY) sets various strings and parameters. SYSTEM has the following
parameters:
SYSTEM (SY) [ [USERVERSION =] x.yy.zz]
[ [LOGONPROMPT =] prompt string]
[ [CIPROMPT =] prompt string]
USERVERSION allows the system manager to identify the system with a version meaningful to your
environment. This might identify some combination of third-party products.
LOGONPROMPT sets the system prompt.
CIPROMPT sets the prompt used by the command interpreter.
Table 7-5 shows the default values for the SYSTEM command parameters:
To set one of the parameters relating to the SYSTEM command, enter the command and at least one parameter
to change. Here are two examples of the keyword and positional formats:
misc>SYSTEM USERVERSION=A.A1.35
misc>SYSTEM A.A1.35 150:
NOTE A changed USERVERSION, as in the previous example, is lost if the MISC configurator
information is saved to the group CONFIG.SYS. The ID information is retained if it is saved to
any group other than CONFIG.SYS. To change user version, generate a system load tape (SLT)
and update with it.
Table 7-5 Default Values for SYSTEM Parameters
Parameter Value
USERVERSION A.50.00
PROMPT MPE/iX:
CIPROMPT :