SNA Link/iX Node Managers Guide (30291-90507)

72 Chapter2
SNA Node and Link Configuration
Configuring the SNA Node and Link
This field is required
only
if PVC is entered for the
Virtual Circuit Type field.
Range: 0-4095 (integer)
X.25 System Access Configuration: If you configured a
specific address key for the SNA/X.25 PVC (in the PVC
Number field of the “X.25 PVC Address Key Paths”
screen), that address key must match the value
specified in this field, refer to Figure 2-9.
DTC Manager Configuration: The range specified for
the LCI Range field (for PVCs) of the “DTC Manager
DTCX25 Board # Level 3” screen must contain the
value specified in this field.
DTS Configuration: The range specified for the LCI
Range field (for PVCs) of the “DTS X.25 Card Config —
Level 3 &Miscellaneous” screen must contain the value
specified in this field.
SVC DATA
Information about the switched virtual circuit (SVC).
Remote’s X.25 Network Address
Conditionally required. The X.25 network address of
the remote system. This is found in the X.25 network
subscription information.
This field is required
only
if SVC is entered for the
Virtual Circuit Type field.
Host Configuration: If the host is configured to make
outgoing calls, the DIALNO operand value of the PATH
macro that defines the dial-out path to the HP e3000
node must contain the value specified in this field, refer
to Table 2-3. For security purposes, SNA/X.25 Link
compares the remote X.25 address contained in
incoming calls with the value specified in this field. See
the HP SNA Products Remote System Configuration
Guide for more information about host configuration.
Also, the features and names of the facility sets are
found in the X.25 network subscription information.
Note that the facility set (the set of virtual circuit
features and security attributes associated with the
SVC) configured on the remote system must also be
configured for the NS X.25 system link.
AS/400 Configuration: The NETADDR parameter in the
line description must match this field, refer to Table
2-8.