SNA Link/iX Node Managers Guide (30291-90507)
Chapter 2 63
SNA Node and Link Configuration
Configuring the SNA Node and Link
15 times at T1 intervals.
Range: (1–15)
Physical interface
Required. The Physical Interface field displays the
cable type that is currently connected to the PSI card,
This data is to be configured through NMMGR. The
possible values are:
0 = RS-232
1 = V.35
Transmit window size
Required. The Transmit Window size (K field) is the
configured number of unacknowledged frames that are
allowed in the network at any given time. For example,
if this value is set to seven (7) for a node, and that node
transmits seven (7) packet frames onto the network, it
cannot transmit another frame until one or more of the
transmitted frames are acknowledged.
Range: 1–7
Connect timeout
Required. The Connect Timeout is the current logical
link level 2 connection timeout. The Connect Timeout
parameter sets the amount of time a node will wait for
a logical connection to a remote node to be established.
If this timer expires, the node aborts the connection
attempt. The abort process can take several additional
seconds.
Range: 5–900 seconds
Clock source
Required. The Clock source field defines the clocking
mode. The possible types of clocking source are:
0 = internal
1 = external)
Adapter timeout
Required. The Adapter Timeout is the value specified
for the Adapter timer. This timer, also called a
heartbeat timer, is used to monitor whether the system
and/or the ACC card are functioning. The ACC card,
and the system, transmit a signal, called a heartbeat
signal, to each other on a specified schedule. If for
example, the heartbeat does not arrive at the ACC card